Richard H Epstein1, Franklin Dexter2, Ira S Hofer3
1From the Department of Anesthesiology, Perioperative Medicine & Pain Management, Miller School of Medicine, University of Miami, Miami, Florida.
Background:
Perioperative hypothermia may increase the incidences of wound infection, blood loss, transfusion, and cardiac morbidity. US national quality programs for perioperative normothermia specify the presence of at least 1 "body temperature" ≥35.5°C during the interval from 30 minutes before to 15 minutes after the anesthesia end time. Using data from 4 academic hospitals, we evaluated timing and measurement considerations relevant to the current requirements to guide hospitals wishing to report perioperative temperature measures using electronic data sources.
Methods:
Anesthesia information management system databases from 4 hospitals were queried to obtain intraoperative temperatures and intervals to the anesthesia end time from discontinuation of temperature monitoring, end of surgery, and extubation. Inclusion criteria included age >16 years, use of a tracheal tube or supraglottic airway, and case duration ≥60 minutes. The end-of-case temperature was determined as the maximum intraoperative temperature recorded within 30 minutes before the anesthesia end time (ie, the temperature that would be used for reporting purposes). The fractions of cases with intervals >30 minutes between the last intraoperative temperature and the anesthesia end time were determined.
Results:
Among the hospitals, averages (binned by quarters) of 34.5% to 59.5% of cases had intraoperative temperature monitoring discontinued >30 minutes before the anesthesia end time. Even if temperature measurement had been continued until extubation, averages of 5.9% to 20.8% of cases would have exceeded the allowed 30-minute window. Averages of 8.9% to 21.3% of cases had end-of-case intraoperative temperatures <35.5°C (ie, a quality measure failure).
Conclusions:
Because of timing considerations, a substantial fraction of cases would have been ineligible to use the end-of-case intraoperative temperature for national quality program reporting. Thus, retrieval of postanesthesia care unit temperatures would have been necessary. A substantive percentage of cases had end-of-case intraoperative temperatures below the 35.5°C threshold, also requiring postoperative measurement to determine whether the quality measure was satisfied. Institutions considering reporting national quality measures for perioperative normothermia should consider the technical and logistical issues identified to achieve a high level of compliance based on the specified regulatory language.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Factors Affecting Body Temperature
Factors may include: