Open and contaminated pediatric pelvic ring injury case report: Fixation without metal
Brian R Dilworth1, John T Riehl2
1University of Louisville Hospital, Louisville, KY, United States.
Introduction:
Pelvic fractures are relatively uncommon in children, accounting for 0.3-7.5% of all pediatric injuries (Gänsslen et al., 2013; Ismail et al., 1996; Peltier, 1965; Galano et al., 2005; Spiguel et al., 2006). This case report describes a pediatric open pelvic injury caused by a crush mechanism between a car and guardrail.
Case:
A 13year old male presented with an open APC 3 pelvic injury after being pinned between a car and guardrail. His definitive treatment included bilateral SI screw placement, as well as a less invasive method for anterior pelvic ring disruption (Internal Brace suture anchor dynamic fixation).
Discussion/Conclusion:
A less invasive method for the anterior pelvic ring was used to avoid additional dissection due to extensive soft tissue loss, and to decrease hardware burden, which lessens the chance of complications such as infection. Suture fixation of the pubic symphysis provided stable fixation to allow healing in the current case of open pelvic fracture.