Evaluation of the capillary electrophoresis method for measurement of immunoglobulin concentration in ewe colostrum
Related Experiment Video
Updated: Aug 10, 2026

Capillary Electrophoresis Separation of Monoclonal Antibody Isoforms Using a Neutral Capillary
Published on: January 16, 2017
V Lopreiato1, C Ceniti1, F Trimboli1
1Department of Health Science, Magna Græcia University of Catanzaro, Catanzaro, Italy, 88100; Interdepartmental Services Centre of Veterinary for Human and Animal Health, Magna Græcia University of Catanzaro, Catanzaro, Italy, 88100.
Abstract:
Capillary electrophoresis (CE) is a technique routinely used in clinical laboratories that allows the separation and quantification of blood serum proteins in a rapid, precise, accurate, and inexpensive manner. Recently, CE has been proposed to separate and measure colostral proteins, but an evaluation of the agreement between CE and radial immunodiffusion (RID) method, currently used to quantify IgG in colostrum, is still lacking. The purpose of this study was to test the ability of a CE instrument, normally used in blood serum protein analysis, to realize the correct quantification of total Ig concentration in ewe colostrum, using RID assay as reference. Colostrum samples (n = 68) were collected from 35 multiparous Sarda ewes at first milking (n = 33) and at 24 h postpartum (n = 35). The mean ± standard deviation of IgG concentration measured by RID and whey colostrum total Ig concentration measured by CE were 54.76 ± 41.82 g/L and 54.70 ± 41.43 g/L, respectively. Lin's concordance correlation coefficient (r = 0.993; 95% confidence interval = 0.989 to 0.996) and linear regression analysis results (RID = 1.0022CE - 0.063; R2 = 0.986) showed an excellent agreement between these 2 methods. Bland-Altman analysis confirmed that CE method can be a suitable alternative to RID: the mean of the differences between CE and RID was -0.055 ± 4.95 g/L (95% confidence interval = -1.25 to 1.14 g/L) and the agreement limits were -9.75 to 9.60 g/L (low limit 95% confidence interval = -11.82 to -7.68 g/L; high limit 95% confidence interval = 7.57 to 11.72 g/L). In conclusion, the current study indicates that CE method may be a reliable tool for the quantification of the total Ig concentration in ewe colostrum.
More Related Videos
09:32Procedure and Key Optimization Strategies for an Automated Capillary Electrophoretic-based Immunoassay Method
Published on: September 10, 2017
07:58Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
Published on: September 19, 2018