Related Experiment Video
Updated: Feb 28, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Upper extremity non-contrast magnetic resonance venography (MRV) compared to contrast enhanced MRV and ultrasound
Ruth P Lim1, Emma Hornsey2, Dinesh Ranatunga3
1Department of Radiology, Austin Health, PO Box 555, Heidelberg, Victoria 3084, Australia; Department of Radiology, The University of Melbourne, Parkville, Victoria 3052, Australia; Department of Surgery, The University of Melbourne, Parkville, Victoria 3052, Australia.
Purpose:
To assess feasibility, image quality and measured venous caliber of non-contrast MRV (NC-MRV) of central and upper extremity veins, compared to contrast-enhanced MRV (CE-MRV) and ultrasound (US) in healthy volunteers.
Materials And Methods:
10 subjects underwent NC-MRV and CE-MRV at 1.5 T, with comparison to US. Two radiologists evaluated MRI for image quality (IQ) and venous caliber.
Results And Conclusions:
NC-MRV is feasible, with inferior IQ but comparable venous caliber measurements CE-MRV (mean 7.9±4.58 mm vs. 7.83±4.62, p=0.13). Slightly larger upper limb caliber measurements were derived for NC-MRV and CE-MRV compared to US (NC-MRV 5.2±1.8 mm, CE-MRV 4.9±1.6 mm, US 4.5±1.8 mm, both p<0.001).
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...