Related Experiment Video
Updated: Feb 28, 2026

A Method to Test the Efficacy of Handwashing for the Removal of Emerging Infectious Pathogens
Published on: June 7, 2017
The uses and limitations of a hand-held germicidal ultraviolet wand for surface disinfection
George Byrns1, Beverly Barham2, Liangcheng Yang1
1a Environmental Health , Illinois State University , Normal , Illinois.
Abstract:
The morbidity and mortality from healthcare associated infections has raised concern that conventional disinfection methods are inadequate and that other adjunct methods such as room fumigation and ultraviolet irradiation may be needed. There is also concern that these alternative methods may pose a risk to workers and patients.
Objectives:
(1) Determine the efficacy of a germicidal UV-C wand for surface disinfection, (2) evaluate changing relative humidity (RH) and different target distances on bacteria kill rates, and (3) assess potential exposure concerns.
Methods:
This study investigates whether a hand-held germicidal wand can efficaciously disinfect surfaces treated with either a vegetative or spore forming bacterium and to evaluate the effect of changing environmental conditions such as relative humidity (RH), target position, and target distances on microbial kill rates.
Results:
Kill rate was best at 40-65% RH at a temperature range of 21-24°C. Both high and low RH interfered with the ability of UV-C to kill the vegetative microbe. In the case of the spore forming bacterium, increased surface drying time was the most significant factor increasing kill rate.
Conclusions:
This research demonstrates that UV-C was efficacious under optimal conditions, a direct beam exposure, and a short target distance (12.7 cm). However, there are limitations when used in non-optimal conditions. Increased distance and indirect beam angles resulted in lower kill rates. It is also important to minimize unnecessary patient and worker exposure during its use.
Related Concept Videos
Hand hygiene
Hand washing...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Chemical Agents for Microbial Control

