Effect of Single-Use, Laser-Cut, Slow-Flow Nipples on Respiration and Milk Ingestion in Preterm Infants
Related Experiment Video
Updated: Feb 28, 2026

Author Spotlight: Implications of Non-Nutritive Sucking on Speech Emergence and Infant Development
Published on: April 19, 2024
Katlyn E McGrattan1, David H McFarland2, Jesse C Dean1
1Department of Health Sciences and Research, Medical University of South Carolina, Charleston.
Purpose:
Single-use, laser-cut, slow-flow nipples were evaluated for their effect on respiration and milk ingestion in 13 healthy preterm infants (32.7-37.1 weeks postmenstrual age) under nonlaboratory, clinical conditions.
Method:
The primary outcomes of minute ventilation and overall milk transfer were measured by using integrated nasal airflow and volume-calibrated bottles during suck bursts and suck burst breaks during slow-flow and standard-flow nipple bottle feedings. Wilcoxon signed-ranks tests were used to test the effect of nipple type on both outcomes.
Results:
Prefeeding minute ventilation decreased significantly during suck bursts and returned to baseline values during suck burst breaks across both slow-flow and standard-flow nipples. No differences were found in minute ventilation (p > .40) or overall milk transfer (p = .58) between slow-flow and standard-flow nipples.
Conclusions:
The lack of difference in primary outcomes between the single-use slow-flow and standard-flow nipples may reflect variability in nipple properties among nipples produced by the same manufacturer. Future investigations examining the effect of both single-use and reusable nipple products are warranted to better guide nipple selection during clinical care.
More Related Videos
09:36Effect of Hyaluronic Acid 35 kDa on an In Vitro Model of Preterm Small Intestinal Injury and Healing Using Enteroid-Derived Monolayers
Published on: July 28, 2022
04:56Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...