Estimation of respiratory volume from thoracoabdominal breathing distances: comparison of two models of machine
Rémy Dumond1,2, Steven Gastinger3,4, Hala Abdul Rahman3,5
1Laboratoire Mouvement, Sport, Santé (EA 1274), Université de Rennes 2, Avenue Robert Schuman, 35170, Bruz, France. remy.dumond@gmail.com.
Purpose:
The purposes of this study were to both improve the accuracy of respiratory volume (V) estimates using the respiratory magnetometer plethysmography (RMP) technique and facilitate the use of this technique.
Method:
We compared two models of machine learning (ML) for estimating [Formula: see text]: a linear model (multiple linear regression-MLR) and a nonlinear model (artificial neural network-ANN), and we used cross-validation to validate these models. Fourteen healthy adults, aged [Formula: see text] years participated in the present study. The protocol was conducted in a laboratory test room. The anteroposterior displacements of the rib cage and abdomen, and the axial displacements of the chest wall and spine were measured using two pairs of magnetometers. [Formula: see text] was estimated from these four signals, and the respiratory volume was simultaneously measured using a spirometer ([Formula: see text]) under lying, sitting and standing conditions as well as various exercise conditions (working on computer, treadmill walking at 4 and 6 km[Formula: see text], treadmill running at 9 and 12 km [Formula: see text] and ergometer cycling at 90 and 110 W).
Results:
The results from the ANN model fitted the spirometer volume significantly better than those obtained through MLR. Considering all activities, the difference between [Formula: see text] and [Formula: see text] (bias) was higher for the MLR model ([Formula: see text] L) than for the ANN model ([Formula: see text] L).
Conclusion:
Our results demonstrate that this new processing approach for RMP seems to be a valid tool for estimating V with sufficient accuracy during lying, sitting and standing and under various exercise conditions.
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Respiratory Volumes and Capacities I
Respiratory Volumes and Capacities
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Application of Integration: Problem Solving
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: