Related Experiment Video
Updated: Feb 28, 2026

Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
Detection of Hb Rothschild HBB: c.[112T>A or 112T>C], Through High Index of Suspicion on Abnormal Pulse Oximetry
Nazeer A Alli1, Piet Wessels2, Narisha Rampersad1
1a Molecular Medicine and Haematology, School of Pathology, National Health Laboratory Service , University of the Witwatersrand , Johannesburg , South Africa.
Abstract:
We describe a case with a low oxygen affinity hemoglobin (Hb) variant who presented with cyanosis in the absence of cardiopulmonary disease. The patient, a 27-year-old pregnant female (P1G2), complained of a productive cough and bluish discoloration of the lips that started 3 days prior to seeking attention. She had no previous episodes and has generally been in good health. A positive family history of cyanosis was obtained in one sibling. Systematic examination, notably the cardiorespiratory system, revealed no abnormalities. The arterial Hb oxygen saturation (SpO2) on pulse oximetry was 81.0% and Hb separation studies revealed an Hb variant identified as Hb Rothschild [β37(C3)Trp→Arg] (HBB: c.[112 T>A or 112 T>C]) by gene sequencing. The amino acid substitution (Trp→Arg) is an important contact point at the α1β2 interface and favors a T-quaternary state of the Hb tetramer. This leads to a low oxygen affinity state, which results in premature release of oxygen and drop in oxygen saturation. In the absence of cardiopulmonary disease, a decreased oxygen saturation reading, with or without cyanosis, should arouse suspicion for a possible dysHb.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
05:18A Rapid and Chemical-free Hemoglobin Assay with Photothermal Angular Light Scattering
Published on: December 7, 2016
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies