Intraoperative Real-Time Assessment of Liver Function with Near-Infrared Fluorescence Imaging
Hajime Narasaki1, Takehiro Noji, Hideyuki Wada
1Department of Gastroenterological Surgery II, Hokkaido University Graduate School of Medicine, Sapporo, Japan.
Background:
Postoperative liver failure is a serious complication after major hepatectomy, and perioperative prediction of its incidence using current technology is still very difficult. Near-infrared (NIR) fluorescence imaging allows quantitative assessment of the fluorescent signal from indocyanine green (ICG) in regions of interest on the liver surface. This method might offer a new promising modality for evaluating regional liver reserve. However, data are lacking regarding the relationship between liver function and fluorescent signals on the liver surface after intravenous ICG injection. This study was conducted to obtain the data necessary to apply NIR fluorescence imaging as a modality for measuring liver function.
Materials And Methods:
This study included 16 patients who underwent open hepatopancreatobiliary surgery between March 2011 and March 2012. After laparotomy, ICG was injected intravenously at 2.5 mg/L of liver volume, then the fluorescence intensity (FI) and signal-to-background ratio (SBR) in the lateral segment of the liver were assessed for 15 min. Intraoperative blood samples were also obtained to measure the plasma clearance rate of ICG (ICGK). Correlations between ICGK, liver volume, and SBR, as well as between ICGK, liver volume, and rate of change of FI were analyzed.
Results:
The experimental procedure was performed in all 16 patients. The FI of the liver increased rapidly after ICG injection, then became more gradual, reaching a near-plateau after 15 min. A significant correlation was seen between ICGK and the rate of change of FI up to 15 min (|rS| = 0.5725, p < 0.05).
Conclusion:
This is the first report to show a relationship between liver function and fluorescent signals on the liver surface after intravenous ICG injection. Intraoperative NIR fluorescence imaging with ICG may be useful as a new method for assessing liver function.