Characterization of SiN Integrated Optical Phased Arrays on a Wafer-Scale Test Station
05:57

Characterization of SiN Integrated Optical Phased Arrays on a Wafer-Scale Test Station

Published on: April 1, 2020

8.6K

Test of a 32-channel Prototype ASIC for Photon Counting Application.

Y Chen1, Y Cui1, P O'Connor1

  • 1Brookhaven National Laboratory, Upton, NY 11973, USA.

IEEE Nuclear Science Symposium Conference Record. Nuclear Science Symposium
|June 20, 2017
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Comparative Study of Lateral K-Wire and Crossed K-wires Fixation for the Management of Gartland Type III Closed Supracondylar Humeral Fracture.

Mymensingh medical journal : MMJ·2026
Same author

Outcome of Primary Total Hip Arthroplasty in Displaced Fracture Neck of Femur in Elderly Patients.

Mymensingh medical journal : MMJ·2026
Same author

Impact of COVID-19 Pandemic in Social Life of Students of Mymensingh Medical College.

Mymensingh medical journal : MMJ·2026
Same author

Does Vitamin D₃ Supplementation Improve Exercise Tolerance of D₃ Deficient Chronic Obstructive Lung Disease Patients? - A Randomized Controlled Trial.

Mymensingh medical journal : MMJ·2026
Same author

Cardiac Arrest Recovery Enablement and Supported Self-management (CARESS): a study protocol for the feasibility testing of an online psychosocial and exercise rehabilitation programme for cardiac arrest survivors and co-survivors.

Resuscitation plus·2026
Same author

The Impact of Covid-19 Pandemic on Personal Life of Undergraduate and Postgraduate Students of Mymensingh Medical College.

Mymensingh medical journal : MMJ·2025

A new low-power application-specific integrated circuit (ASIC) for Cadmium Zinc Telluride (CZT) detectors was developed for single-photon emission computed tomography (SPECT). The 32-channel prototype ASIC demonstrates excellent performance with low power consumption and minimal noise.

Area of Science:

  • Medical Imaging
  • Detector Electronics
  • Semiconductor Technology

Background:

  • Single-photon emission computed tomography (SPECT) requires advanced detector electronics for improved imaging.
  • Cadmium Zinc Telluride (CZT) detectors offer high-resolution photon detection for SPECT applications.
  • Low-power, high-performance integrated circuits are crucial for compact and efficient SPECT systems.

Purpose of the Study:

  • To develop and test a novel low-power application-specific integrated circuit (ASIC) for CZT detectors used in SPECT.
  • To evaluate the performance characteristics of a 32-channel prototype ASIC, including power consumption, noise, and linearity.
  • To demonstrate the feasibility of using custom CMOS ASICs for next-generation SPECT systems.

Main Methods:

Keywords:
CZTMulti-channelPhoton CountingTestlow-power ASIC

More Related Videos

Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source
12:19

Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source

Published on: April 4, 2017

8.9K
A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
07:56

A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference

Published on: September 5, 2019

9.0K

Related Experiment Videos

Last Updated: Feb 28, 2026

Characterization of SiN Integrated Optical Phased Arrays on a Wafer-Scale Test Station
05:57

Characterization of SiN Integrated Optical Phased Arrays on a Wafer-Scale Test Station

Published on: April 1, 2020

8.6K
Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source
12:19

Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source

Published on: April 4, 2017

8.9K
A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
07:56

A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference

Published on: September 5, 2019

9.0K
  • Designed and fabricated a 32-channel prototype ASIC using TSMC 0.35-μm CMOS technology.
  • Integrated preamplifiers, CR-RC³ shaping circuits, and energy binning with comparators and counters.
  • Characterized the ASIC's performance, including power consumption, Equivalent Noise Charge (ENC), crosstalk, and Digital-to-Analog Converter (DAC) linearity.
  • Main Results:

    • Achieved low power consumption of approximately 1 mW/channel at a 2.5-V supply.
    • Measured an Equivalent Noise Charge (ENC) of 360 electrons at room temperature with a peaking time of 500 ns.
    • Demonstrated low crosstalk (<0.3%) and excellent DAC linearity (INL <0.56%, DNL <0.33%).

    Conclusions:

    • The developed 32-channel ASIC is a promising low-power solution for CZT detectors in SPECT.
    • The measured performance metrics meet the requirements for advanced medical imaging applications.