New Insights into the Wavelength Dependence of MALDI Mass Spectrometry
Marcel Niehaus1, Andreas Schnapp1, Annika Koch1
1Institute for Hygiene, Biomedical Mass Spectrometry, University of Münster , D-48149 Münster, Germany.
Abstract:
The interplay between the wavelength of the laser and the absorption profile of the matrix constitutes a crucial factor in matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). Numerous studies have shown that typically best analytical results are obtained if the laser wavelength matches the UV absorption band of the matrix in the solid state well. However, many powerful matrices exhibit peak absorptions which differ notably from the standard MALDI laser wavelengths of 337, 349, and 355 nm, respectively. Here we used two wavelength-tunable lasers to investigate the MALDI wavelength dependence with a selected set of such matrices. We studied 3-hydroxypicolinic acid (3-HPA), 2,4,6-trihydroxyacetophenon (THAP), dithranol (1,8-dihydroxy-10H-anthracen-9-on), 2-(4'-hydroxybenzeneazo)benzoic acid (HABA), and 6-aza-2-thiothymine (ATT). For analyte systems we investigated DNA oligomers (3-HPA), phospholipids (dithranol, THAP, HABA), and non-covalent peptide-peptide and protein-peptide complexes (ATT). We recorded analyte ion and total ion counts as a function of wavelength and laser fluence between 213 and 600 nm. Although the so-generated comprehensive heat maps generally corroborated the previously made findings, several fine features became notable. For example, despite a still high optical absorption exhibited by some of the matrices in the visible wavelength range, ion yields generally dropped strongly, indicating a change in ionization mechanism. Moreover, the non-covalent complexes were optimally detected at wavelengths corresponding to a relatively low optical absorptivity of the ATT matrix, presumably because of ejection of a particular cold MALDI plume. Our comprehensive data shed useful light into the MALDI mechanisms and could assist in further methodological advancement of the technique.
More Related Videos
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight MALDI-TOF Mass Spectrometry
Published on: June 10, 2018
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
Related Concept Videos
MALDI-TOF Mass Spectrometry
Matrix-Assisted Laser Desorption Ionization (MALDI)
Mass Spectrometry: Isotope Effect
Mass Spectrum: Interpretation
Mass Spectrometry: Overview
Tandem Mass Spectrometry