Related Experiment Video
Updated: Jul 19, 2026

Rapid Identification of Gram Negative Bacteria from Blood Culture Broth Using MALDI-TOF Mass Spectrometry
Published on: May 28, 2014
Parallel Evaluation of the MALDI Sepsityper and Verigene BC-GN Assays for Rapid Identification of Gram-Negative
Miguel A Arroyo1,2, Gerald A Denys3
1Department of Pathology and Laboratory Medicine, Indiana University School of Medicine, Indianapolis, Indiana, USA.
Abstract:
Rapid identification of microorganisms from positive blood cultures has improved clinical management and antimicrobial stewardship. The advent of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has reduced the time to identification of cultured isolates and is now often the definitive method used in the clinical microbiology laboratory. The commercial in vitro diagnostic MALDI Sepsityper (Sepsityper) kit has the potential for standardization and clinical routine use for the rapid identification of a broad range of bacteria from positive blood cultures. In this study, we performed a parallel evaluation of the Sepsityper (Bruker Daltonics, Billerica, MA) and the Verigene BC-GN (BC-GN) assays (Nanosphere, Inc., Northfield, IL) for the identification of Gram-negative bacilli. A total of 210 Bactec bottles demonstrating Gram-negative bacilli were prospectively enrolled for this study. Among these, 200 monomicrobial cultures were included in the comparative analysis. For monomicrobial cultures, the BC-GN detected 85% (170/200) compared to that detected by routine culture while the Sepsityper detected 94% (188/200) and 91% (181/200) to the genus and species levels, respectively. Comparable positive percentage agreement and negative percentage agreement were observed between the Sepsityper (96.5% and 98.8%, respectively) and the BC-GN (99.4% and 99.8%, respectively) when only (n = 170, 85%) organisms targeted by the latter test were included in the analysis. In conclusion, the two methods evaluated in this study showed excellent performance characteristics for the identification of Gram-negative bacilli commonly isolated from blood cultures. The Sepsityper showed a broader identification range capability that may further improve clinical management and antimicrobial stewardship in patients with less frequent Gram-negative bacilli bloodstream infections.
More Related Videos
11:25Preparation of a Blood Culture Pellet for Rapid Bacterial Identification and Antibiotic Susceptibility Testing
Published on: October 15, 2014
09:07Author Spotlight: Accelerating Diagnostic Accuracy with Direct Identification of Gram-Negatives from Blood Culture Bottles
Published on: May 24, 2024
Related Concept Videos
Rapid Identification of Pathogens
Automated Microbial Diagnostics