Feasibility of Focused Beam Reflectance Measurement (FBRM) for Analysis of Pharmaceutical Suspensions in Preclinical

Kaushalkumar Dave1,2, Paul E Luner3, Cecile Forness4

  • 1Material and Analytical Sciences, Boehringer Ingelheim Pharmaceuticals, Inc., Ridgefield, Connecticut, 06877, USA. davekaushal@gmail.com.

AAPS Pharmscitech
|June 23, 2017
PubMed

Related Concept Videos

Drug Dissolution: Requirements and Profile Comparison01:14

Drug Dissolution: Requirements and Profile Comparison

The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...
340
Clinically Relevant Drug Product Specifications: Methods of Establishment01:29

Clinically Relevant Drug Product Specifications: Methods of Establishment

Product specifications define the acceptable quality of a pharmaceutical product by ensuring identity, purity, potency, and strength. These specifications serve as benchmarks during development, manufacturing, and post-approval quality control. Clinically relevant specifications are particularly important because they directly relate to a drug's safety and efficacy in clinical use.Dissolution studies are critical biopharmaceutic tools that link in vitro behavior to in vivo performance. They...
275
Measurement of Bioavailability: Pharmacodynamic Methods01:20

Measurement of Bioavailability: Pharmacodynamic Methods

Pharmacodynamic methods provide insights into a drug's effects on physiological processes over time and play a crucial role in understanding bioavailability and therapeutic efficacy. These methods can be broadly classified into acute pharmacological and therapeutic response approaches, each with distinct mechanisms and applications.The acute pharmacological response method directly correlates a drug's physiological effects, such as ECG or pupil diameter changes, to its time course in the body.
923
In Vitro Drug Dissolution: Alternative Methods01:17

In Vitro Drug Dissolution: Alternative Methods

Alternative drug dissolution methods include the rotating bottle, intrinsic dissolution test, peristalsis, and the Franz diffusion cell method. The rotating bottle method involves meticulously rotating tightly capped controlled-release beads in a temperature-controlled bath. Periodic decanting of samples allows for residue assay, followed by refilling with fresh medium and testing at various pH levels to emulate the gastrointestinal tract conditions.In contrast, the intrinsic dissolution test...
291