Measuring the Motor Aspect of Cancer-Related Fatigue using a Handheld Dynamometer
Published on: February 20, 2020
Comparison of Jamar and Bodygrip Dynamometers for Handgrip Strength Measurement
Rita S Guerra1, Teresa F Amaral, Ana S Sousa
11Department of Biochemistry, Faculty of Medicine, University of Porto, Porto, Portugal;2System Integration and Process Automation Research Unit-Institute of Science and Innovation in Mechanical and Industrial Engineering, Faculty of Engineering, University of Porto, Porto, Portugal;3Porto Hospital Center, Porto, Portugal; and4Faculty of Nutrition and Food Sciences, University of Porto, Porto, Portugal.
Abstract:
Guerra, RS, Amaral, TF, Sousa, AS, Fonseca, I, Pichel, F, and Restivo, MT. Comparison of Jamar and Bodygrip dynamometers for handgrip strength measurement. J Strength Cond Res 31(7): 1931-1940, 2017-Studies that compared the agreement between Jamar and other models of dynamometers for handgrip strength (HGS) measurement have exhibited variability in the provided results. The lack of comparability between dynamometers led to the development of the Bodygrip dynamometer. This study aims to examine the reliability of the Bodygrip for HGS measurement, to compare it with the Jamar, and to explore the HGS differences between instruments considering the ergonomic effect of using the Bodygrip with 2 different handles. A cross-sectional study was conducted in free-living (n = 114, 18-89 years) and inpatient (n = 50, 65-93 years) volunteers. Nondominant HGS was tested randomly with the Jamar and Bodygrip, the latter using 2 different handles-curved and straight types. Handgrip strength was obtained for each participant under the same conditions. Each individual performed 2 HGS measurements with each dynamometer, and the maximum HGS value was considered for dynamometers comparison. Differences in the maximum HGS value between the 2 devices (Jamar-Bodygrip), intraclass correlation coefficients (ICCs), Bland and Altman plots, and limits of agreement were obtained. Correlation between the highest HGS measurement obtained for the nondominant hand with the Jamar and with the Bodygrip using each handle was excellent (ICCs: 0.93-0.95). Mean differences of -0.5 (limits of agreement: -4.6; 3.5) kgf with the curved handle and of 1.0 (-7.7; 9.7) kgf with the straight handle for the free-living participants were obtained, whereas for inpatients these values were -1.0 (-3.8; 1.9) kgf and 2.1 (-3.3; 7.5) kgf, respectively, for the curved and straight handles. The Bodygrip is comparable to the Jamar in free-living adults and in hospitalized older adults, exhibiting excellent interinstrument reliability. The Bodygrip with the curved handle produces results closer to the Jamar when compared with Bodygrip with the straight handle, which emphasizes the importance of grip handle ergonomics to measurement reliability.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Measurement of Blood Pressure
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...