Related Experiment Video
Updated: Feb 27, 2026

High-throughput Detection Method for Influenza Virus
Published on: February 4, 2012
Comparison of mucosal lining fluid sampling methods and influenza-specific IgA detection assays for use in human
Thushan I de Silva1, Victoria Gould2, Nuredin I Mohammed3
1Section of Paediatrics, Imperial College London, St Mary's Campus, London, W2 1PG, UK; Sheffield Teaching Hospitals NHS Foundation Trust, Royal Hallamshire Hospital, Glossop Road, Sheffield, S10 2JF, UK; Vaccines and Immunity Theme, Medical Research Council Unit The Gambia, PO Box 273, Banjul, Gambia.
Abstract:
We need greater understanding of the mechanisms underlying protection against influenza virus to develop more effective vaccines. To do this, we need better, more reproducible methods of sampling the nasal mucosa. The aim of the current study was to compare levels of influenza virus A subtype-specific IgA collected using three different methods of nasal sampling. Samples were collected from healthy adult volunteers before and after LAIV immunization by nasal wash, flocked swabs and Synthetic Absorptive Matrix (SAM) strips. Influenza A virus subtype-specific IgA levels were measured by haemagglutinin binding ELISA or haemagglutinin binding microarray and the functional response was assessed by microneutralization. Nasosorption using SAM strips lead to the recovery of a more concentrated sample of material, with a significantly higher level of total and influenza H1-specific IgA. However, an equivalent percentage of specific IgA was observed with all sampling methods when normalized to the total IgA. Responses measured using a recently developed antibody microarray platform, which allows evaluation of binding to multiple influenza strains simultaneously with small sample volumes, were compared to ELISA. There was a good correlation between ELISA and microarray values. Material recovered from SAM strips was weakly neutralizing when used in an in vitro assay, with a modest correlation between the level of IgA measured by ELISA and neutralization, but a greater correlation between microarray-measured IgA and neutralizing activity. In conclusion we have tested three different methods of nasal sampling and show that flocked swabs and novel SAM strips are appropriate alternatives to traditional nasal washes for assessment of mucosal influenza humoral immunity.
More Related Videos
06:34An Optimized Hemagglutination Inhibition HI Assay to Quantify Influenza-specific Antibody Titers
Published on: December 1, 2017
12:09Measuring Influenza Neutralizing Antibody Responses to AH3N2 Viruses in Human Sera by Microneutralization Assays Using MDCK-SIAT1 Cells
Published on: November 22, 2017