RPLC-HILIC and SFC with Mass Spectrometry: Polarity-Extended Organic Molecule Screening in Environmental (Water)
Stefan Bieber1, Giorgia Greco1, Sylvia Grosse1
1Analytical Research Group, Chair of Urban Water Systems Engineering, Technical University of Munich , Am Coulombwall 3, 85748 Garching, Germany.
Abstract:
Trace organic compounds are important in environmental analysis because they impact water quality and introduce potential (eco)toxicological effects. Current analytical methods mostly rely on gas chromatography (GC) or reversed-phase liquid chromatography (RPLC) coupled with (tandem) mass spectrometry. However, neither method can easily separate very polar molecules. This study presents two chromatographic separation strategies, a serial RPLC-hydrophilic interaction liquid chromatography (RPLC-HILIC) coupling and an analytical scale supercritical fluid chromatography (SFC) system, and validates their separation effectiveness as polarity-extended chromatographic methods for 274 environmentally relevant compounds. Compounds tested were grouped into three polarity classes, "very polar" {log D (pH 7) below -2.5}, "polar" {log D (pH 7) -2.5 to +2}, and "non-polar" {log D (pH 7) higher than +2}). Nearly all compounds could be retained in both systems with relative standard deviations of retention times (RT; n = 6) typically between 2 and 5%. Both techniques have considerable benefits when combined with accurate mass spectrometric detection. Molecules RT and accurate mass were recorded in a database for each set up. This information was used for compound screening measurements like "hidden-target screening" in complex environmental matrices (such as wastewater treatment plant effluents). Results of both techniques are complementary and useful for all types of molecules polarity. In this study, more than 80% of the compounds found in wastewater treatment plant effluent samples possessed a negative log D (pH 7) value. This result highlights the basic necessity to include "very polar" compounds in water monitoring techniques and protocols.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
10:34Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Analyte Adsorption and Distribution
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...