Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

International expert consensus on gene therapy for hereditary hearing loss: Based on clinical trials.

Med (New York, N.Y.)·2025
Same author

Treating Hearing Loss: From Cochlear Implantation to Gene Therapy.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2025
Same author

Clinical gene therapy restores hearing: a paradigm shift.

Trends in molecular medicine·2025
Same author

AAV gene therapy for autosomal recessive deafness 9: a single-arm trial.

Nature medicine·2025
Same author

Can cognitive performance predict individual differences in speech recognition at a cocktail party?

Hearing research·2025
Same author

Evaluating synthesized speech intelligibility in noise.

JASA express letters·2025
Same journal

Magnetic Resonance Spectroscopy Deep Learning with Magnetic Resonance Background Generator Enables In Vivo Metabolite Quantification of Hepatic Encephalopathy.

IEEE transactions on bio-medical engineering·2026
Same journal

Use of RPNIs and Implanted Electrodes for Prosthetic Wrist and Multi-Grip Hand Control during Functional Tasks: A Case Study.

IEEE transactions on bio-medical engineering·2026
Same journal

Healthy Limb Driven Prediction for Real Time Control of Unilateral Exoskeletons in Gait Rehabilitation.

IEEE transactions on bio-medical engineering·2026
Same journal

A Miniature Wearable Ultrasound System for Continuous Bladder Monitoring with Sleeping-Position-Robust Modeling Strategies.

IEEE transactions on bio-medical engineering·2026
Same journal

A Bi-objective Array Optimization Framework for Magnetocardiographic Source Imaging.

IEEE transactions on bio-medical engineering·2026
Same journal

A Dynamic Mutual Information Measure of Phase-Amplitude Coupling with Uncertainty Quantification.

IEEE transactions on bio-medical engineering·2026
See all related articles

Related Experiment Video

Updated: Feb 27, 2026

Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
06:04

Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages

Published on: March 24, 2023

899

Challenges in Improving Cochlear Implant Performance and Accessibility.

Fan-Gang Zeng

    IEEE Transactions on Bio-Medical Engineering
    |June 27, 2017
    PubMed
    Summary
    This summary is machine-generated.

    Cochlear implants face performance limits due to electrode size and quantity, hindering hearing restoration. High costs also restrict access, necessitating research and business strategy changes for wider adoption.

    More Related Videos

    Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
    07:00

    Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process

    Published on: June 21, 2024

    1.6K
    Robotic Cochlear Implantation for Direct Cochlear Access
    08:06

    Robotic Cochlear Implantation for Direct Cochlear Access

    Published on: June 16, 2022

    4.2K

    Related Experiment Videos

    Last Updated: Feb 27, 2026

    Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
    06:04

    Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages

    Published on: March 24, 2023

    899
    Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
    07:00

    Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process

    Published on: June 21, 2024

    1.6K
    Robotic Cochlear Implantation for Direct Cochlear Access
    08:06

    Robotic Cochlear Implantation for Direct Cochlear Access

    Published on: June 16, 2022

    4.2K

    Area of Science:

    • Biomedical Engineering
    • Neuroscience
    • Hearing Science

    Background:

    • Cochlear implant performance has plateaued despite increased research.
    • A significant gap exists between electrode size and neuron diameter.
    • The limited number of electrodes restricts frequency resolution.

    Purpose of the Study:

    • Identify key limitations in cochlear implant technology.
    • Address the electrode-to-neuron interface challenges.
    • Explore strategies to improve cochlear implant accessibility and affordability.

    Main Methods:

    • Analysis of cochlear implant electrode design limitations.
    • Review of market penetration data and cost factors.
    • Discussion of potential research and business model innovations.

    Main Results:

    • Electrode size (1000x neuron diameter) and quantity (1000x fewer) cause broad spatial activation and poor frequency resolution.
    • High cochlear implant costs limit market penetration (<20% developed, <1% developing countries).

    Conclusions:

    • Improving electrode-neuron interface is crucial for enhanced cochlear implant performance.
    • Addressing cost barriers is essential for equitable access to hearing restoration technology.
    • Strategic shifts in research and business are needed to bridge the hearing and access gaps.