Oxygen-Flow-Pressure Targets for Resuscitation in Critical Hemodynamic Therapy
Huaiwu He1, Yun Long, Xiang Zhou
1Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China.
Abstract:
Far from traditional "vital signs," the field of hemodynamic monitoring (HM) is rapidly developing. However, it is also easy to misunderstand hemodynamic therapy as merely HM and some concrete bundles or guidelines for circulation support. Here, we describe the concept of "critical hemodynamic therapy" and clarify the concepts of the "therapeutic target" and "therapeutic endpoint" in clinical practice. Three main targets (oxygen delivery, blood flow, perfusion pressure) for resuscitation are reviewed in critically ill patients according to the sepsis guidelines and hemodynamic consensus. ScvO2 at least 70% has not been recommended as a directed target for initial resuscitation, and the directed target of mean arterial pressure (MAP) still is 65 mmHg. Moreover, the individual MAP target is underlined, and using flow-dependent monitoring to guide fluid infusion is recommended. The flow-directed target for fluid infusion might be a priority, but it remains controversial in resuscitation. The interpretation of these targets is necessary for adequate resuscitation and the correction of tissue hypoxia. The incoherence phenomenon of resuscitation (macrocirculation and microcirculation, tissue perfusion, and cellular oxygen utilization) is gaining increased attention, and early identification of these incoherences might be helpful to reduce the risk of over-resuscitation.
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Cardiopulmonary Resuscitation IV: Pharmacological Management
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...