Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Microblasting Wound Dressings Mechanically Disrupt Polymicrobial Biofilms to Enhance Healing in Treatment-Resistant Wounds.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026
Same author

Surface versus Nanocatalyst-Induced Matrix Bubbles Govern Temperature-Dependent Biofilm Removal.

ACS applied materials & interfaces·2026
Same author

Real-time, high-resolution metabolic characterization of live bacteria using label-free optical metabolic imaging.

NPJ biofilms and microbiomes·2026
Same author

Clinical trial assessing the use of optical coherence tomography in decision making for children presenting with acute otitis media.

International journal of pediatric otorhinolaryngology·2026
Same author

Texture-based speciation of otitis media-related bacterial biofilms from optical coherence tomography images using supervised classification.

Journal of biophotonics·2024
Same author

Fine-tuning TrailMap: The utility of transfer learning to improve the performance of deep learning in axon segmentation of light-sheet microscopy images.

PloS one·2024
Same journal

Computational Model for Synthesizing Auditory Brainstem Responses to Assess Neuronal Alterations in Aging and Autistic Animal Models.

Journal of the Association for Research in Otolaryngology : JARO·2026
Same journal

Deaf Acoustics: Listening Through Hearing Aids with Thomas Edison.

Journal of the Association for Research in Otolaryngology : JARO·2026
Same journal

Correction: A Structural Equation Approach to Characterizing Growth and Nonlinearity Underlying Distortion Product Otoacoustic Emissions.

Journal of the Association for Research in Otolaryngology : JARO·2026
Same journal

A Structural Equation Approach to Characterizing Growth and Nonlinearity Underlying Distortion Product Otoacoustic Emissions.

Journal of the Association for Research in Otolaryngology : JARO·2026
Same journal

Age-dependent Shifts in Spiral Ganglion Neuron Subtypes Are Associated with Interphase Gap-dependent Modulation of Electrically Evoked Compound Action Potentials in Mice.

Journal of the Association for Research in Otolaryngology : JARO·2026
Same journal

Bayesian Uncertainty Quantification for A Fractional-Order Model of the Human Ear.

Journal of the Association for Research in Otolaryngology : JARO·2026
See all related articles

Related Experiment Video

Updated: Feb 27, 2026

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
12:22

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT

Published on: August 4, 2018

9.0K

Quantitative Pneumatic Otoscopy Using a Light-Based Ranging Technique.

Ryan L Shelton1, Ryan M Nolan1, Guillermo L Monroy1,2

  • 1Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 N. Mathews Ave, Urbana, IL, 61801, USA.

Journal of the Association for Research in Otolaryngology : JARO
|June 28, 2017
PubMed
Summary
This summary is machine-generated.

A new optical technique accurately detects middle ear fluid in children, a common cause of hearing loss. This non-invasive method assesses eardrum health and infection, improving diagnosis of otitis media.

Keywords:
biomechanicsimagingmiddle ear effusionoptical coherence tomographyotitis media

More Related Videos

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
11:21

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography

Published on: January 15, 2013

12.0K
Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
06:55

Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses

Published on: June 6, 2017

8.0K

Related Experiment Videos

Last Updated: Feb 27, 2026

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
12:22

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT

Published on: August 4, 2018

9.0K
Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
11:21

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography

Published on: January 15, 2013

12.0K
Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
06:55

Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses

Published on: June 6, 2017

8.0K

Area of Science:

  • Biomedical Optics
  • Otolaryngology
  • Medical Diagnostics

Background:

  • Otitis media is a primary cause of pediatric hearing loss, often involving middle ear effusions.
  • Current diagnostic tools for otitis media with effusion offer limited insight into underlying infections.
  • Accurate assessment of middle ear effusions is crucial for understanding otitis media's impact.

Purpose of the Study:

  • To develop and evaluate a novel non-invasive optical technique for diagnosing middle ear conditions.
  • To quantify eardrum thickness, integrity, and detect middle ear effusions, purulence, or biofilm.
  • To measure tympanic membrane mobility using pneumatic low-coherence interferometry.

Main Methods:

  • Low-coherence interferometry, a non-invasive optical technique, was employed to sense depth-resolved scattering features through the eardrum.
  • The technique was integrated with a pneumatic otoscope to measure tympanic membrane deflections in response to pressure stimuli.
  • A pilot study involving 15 subjects was conducted to assess the technique's diagnostic capabilities.

Main Results:

  • Pneumatic low-coherence interferometry successfully quantified eardrum thickness and integrity.
  • The technique demonstrated the ability to detect effusion, purulence, and biofilm behind the tympanic membrane.
  • Quantitative measurements differentiated normal ears from those with effusions in a pilot study.

Conclusions:

  • Pneumatic low-coherence interferometry offers a promising non-invasive method for diagnosing middle ear effusions in children.
  • This technique provides quantitative insights into eardrum dynamics and infection presence.
  • Further research is warranted to explore the full potential and clinical application of this technology.