Related Experiment Video
Updated: Feb 27, 2026

Author Spotlight: Developing a Bedside Protocol for Kidney and Genitourinary Ultrasonography
Published on: June 21, 2024
Sonographic localization of a retained urethral foreign body in an elderly patient
Hamid Shokoohi1, Zachary Kendrick2, Neal Sikka3
1Emergency Ultrasound Fellowship, Department of Emergency Medicine, George Washington University Medical Center, 2120 L Street NW, Suite 450, Washington, DC, 20037.
Abstract:
A retained urethral foreign body is an uncommon presentation in the Emergency Department. The diagnosis and treatment of retained urethral foreign bodies are determined by their size, location, shape, and mobility and often require specialty consultation and operative intervention. In this case of a 74-year-old man with a self-inserted, retained urethral foreign body, we present the utility of a bedside ultrasound to detect the depth, size, and distance from the meatus of the object to guide the approach to extraction of the object at the bedside in the Emergency Department. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 46:296-298, 2018.
Related Concept Videos
Imaging Studies II: Ultrasonography
Urologic Endoscopic Procedure: Cystoscopic Examination
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Urinary Tract Calculi VI: Surgical Management
Urinary Tract Calculi III: Medical Management
Imaging Studies I: Kidney, Ureter, and Bladder Studies