Published on: November 22, 2016
Different PEEK qualities irradiated with light of different wavelengths: Impact on Martens hardness
Nina Lümkemann1, Marlis Eichberger1, Bogna Stawarczyk1
1Department of Prosthodontics, Dental School, Ludwig-Maximilians University Munich, Goethestrasse 70, 80336 Munich, Germany.
Objectives:
To assess the impact of irradiation on Martens hardness parameters of different PEEK qualities filled with titanium dioxide (TiO2), namely PEEK/0%, PEEK/20%, and PEEK/>30%.
Methods:
For Martens hardness (HM) measurements, 40 specimens of each PEEK quality were fabricated and air-abraded with 50μm Al2O3. HM parameters of PEEK specimens were measured initially and stepwise after irradiating for 5, 10, 20, 30, 40, 60, 80, 100, 180, 360 and 540s using light units with different wavelength: Elipar S10 (430-480nm), EyeVolutionMAX (385-390nm+465-470nm), Translux CL (380-500nm) and bre.Lux Power Unit (370-500nm). HM parameters of 10 human teeth were measured initially on enamel and dentin. Data was analysed using 3-way ANOVA with partial eta-squared (ηP2) and post-hoc Tuckey-HSD-test (p<0.05).
Results:
PEEK qualities followed by the wavelength showed the highest effect on Martens hardness (p<0.013). PEEK/>30% (197.35±19.9N/mm2), followed by PEEK/20% (191.45±15.49 N/mm2) showed significantly higher values for HM than PEEK/0% (189.55±16.89N/mm2). PEEK/>30% (5.49±0.4kN/mm) and PEEK/20% (5.38±0.26kN/mm2) presented higher indentation modulus (EIT) than PEEK/0% (4.77±0.36kN/mm2). Irradiated with wavelength of 430-480nm (PEEK/0%: 193.28N/mm2, PEEK20%: 198.83N/mm2, PEEK/>30%: 200.5N/mm2) indicated higher HM compared to specimens irradiated with 380-500nm (PEEK/0%: 186.63N/mm2, PEEK20%: 191.05N/mm2, PEEK/>30%: 196.13N/mm2). Irradiation using 430-480nm (PEEK/0%: 4.95kN/mm2, PEEK20%: 5.52kN/mm2, PEEK/>30%: 5.59kN/mm2) and 370-500nm (PEEK/0%: 4.92kN/mm2, PEEK20%: 5.43kN/mm2, PEEK/>30%: 5.53kN/mm2) indicated higher EIT values compared to specimens irradiated with 380-500nm (PEEK/0%: 4.72kN/mm2, PEEK20%: 5.34kN/mm2, PEEK/>30%: 5.47kN/mm2). Duration of irradiation presented no impact on results. Enamel (HM: 2263.6±405.16, EIT: 63.16±19.24) and dentin (HM: 468.2±30.77N/mm2, EIT: 14.14±4.59kN/mm2) presented significantly higher HM and EIT than the tested PEEK qualities (p<0.001).
Significance:
Irradiation with different wavelength impacted HM parameter. The increase of TiO2 percentage in PEEK matrix improved the HM parameter. However, PEEK showed significantly lower HM parameter than human teeth.
More Related Videos
06:16Author Spotlight: Establishing an Accurate Microhardness Testing Protocol for Craniofacial Tissues
Published on: April 26, 2024
11:47Characterization of Surface Modifications by White Light Interferometry: Applications in Ion Sputtering, Laser Ablation, and Tribology Experiments
Published on: February 27, 2013
Related Concept Videos
Toughness and Hardness of Aggregate
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Plastic Behavior
Brick Durability, Strength, and Appearance