Central venous pressure monitoring via peripherally or centrally inserted central catheters: a systematic review and
Filippo Sanfilippo1, Alberto Noto2, Gennaro Martucci1
1Department of Anesthesia and Intensive Care, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo - Italy.
Introduction:
The central venous pressure (CVP) is the most commonly used static marker of preload for guiding fluid therapy in critically ill patients, though its usefulness remains controversial. Centrally inserted central catheters (CICCs) are the gold-standard devices for CVP monitoring but peripherally inserted central catheters (PICCs) may represent a valid alternative. We undertook a systematic review and meta-analysis with the aim to investigate whether the difference between PICC- and CICC-measured CVP is not significant.
Methods:
We searched for clinical studies published in PubMed and EMBASE databases from inception until December 21st 2016. We included studies providing data on paired and simultaneous CVP measurement from PICCs and CICCs. We conducted two analyses on the values of CVP, the first one according to the total number of CVP assessments, the second one considering the number of patients recruited.
Results:
Four studies matched the inclusion criteria, but only three of them provided data for the meta-analyses. Both analyses showed non-significant differences between PICC-measured and CICC-measured CVP: 1489 paired simultaneous CVP assessments (MD 0.16, 95%CI -0.14, 0.45, p = 0.30) on a total of 57 patients (MD 0.22, 95%CI -1.46, 1.91, p = 0.80). Both analyses showed no heterogeneity (I2 = 0%).
Conclusions:
Available evidence supports that CVP monitoring with PICCs is accurate and reproduces similar values to those obtained from CICCs. The possibility to monitor CVP should not be used among clinical criteria for preferring a CICC over a PICC line.
More Related Videos
05:51Computed Tomography (CT) Guided Implantation of a Totally Implantable Venous Access Port (TIVAP) through Subclavian Vein
Published on: January 13, 2026
09:57A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Related Concept Videos
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Venous Thrombosis III: Interprofessional Care
Cardiac Catheterization II: Right Heart Catheterization
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...