Visual acuity and image quality in 5 diffractive intraocular lenses
Genís Cardona1, Fidel Vega1, Miguel A Gil2
11 Applied Optics and Image Processing Group, Department of Optics and Optometry, Polytechnic University of Catalonia Barcelona Tech, Terrassa - Spain.
Purpose:
To compare objective image quality at distant, intermediate, and near foci with the corresponding visual acuity (VA) in patients symmetrically implanted with 5 different diffractive multifocal intraocular lenses (IOLs) (ReSTOR SV25T0, Tecnis ZKB00, Tecnis ZLB00, AT LISA 809, and AT LISA Tri 839MP) and a monofocal lens (Tecnis ZA9003) 3 months after cataract intervention.
Methods:
Objective image quality, measured as the area under the modulation transfer function curve (AMTF), was tested in vitro in an eye model. In addition, corrected distance visual acuity and distance-corrected intermediate and near visual acuities (DCIVA and DCNVA) were assessed in a group of 79 patients, randomly implanted with one of the lenses.
Results:
Image quality and VA at the distant focus was good for all lens designs, but was similarly compromised at the intermediate focus, where the best DCIVA corresponded to the low add ZKB00. At the near focus, the monofocal lens and the distance dominant SV25T0 had the worst AMTF values, with the ZLB00 presenting the best DCNVA. The relationship between AMTF and VA was found not to be linear, with VA being similarly good for AMTF values over a certain threshold.
Conclusions:
Visual acuity of pseudophakic patients reflected the optical quality of the specific IOL design within a certain range of measurements, beyond which maximum VA is limited by other ocular, optical, and neuropsychophysical factors.
More Related Videos
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Related Concept Videos
Focusing of Light in the Eye
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...