Abstract:
In this article, we present the case of a patient with a stiff, painful knee after total knee arthroplasty, and with erythrocyte sedimentation rate, C-reactive protein level, and synovial fluid analysis within normal limits. Open biopsy for cultures showed Propionibacterium acnes prosthetic joint infection, which was successfully treated with 2-stage revision and intravenous antibiotics.
Related Concept Videos
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Urinary Tract Infection II: Pathophysiology
Endocarditis I: Introduction
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.
Urinary Tract Infection I: Introduction
Acute Pyelonephritis II: Diagnostic Studies and Management