Validation of a novel nonlinear black box Wiener System model for arterial pulse transmission
1Cardiovascular Engineering, Modeling and Medical Devices Lab at Rutgers University, Piscataway, NJ, United States; Electrical and Computer Engineering Dept, United States.
Abstract:
Numerous linear dynamic models exist for describing the arterial pulse transmission phenomenon. We introduce a novel Wiener system based model in which a linear filter representing large arteries is coupled with a hysteresis-free nonlinear function representing complex wave transmission of branching arteries and the periphery. Experimental datasets (n = 7) are used to first estimate the Wiener model with linear, quadratic and cubic function for the aorta to radial artery pulse transmission and aorta to femoral artery pulse transmission. To model the nonlinear memoryless monotonic function in the Wiener System model, a correlation study is performed for linear finite impulse response (FIR) filter simulated peripheral pressure vs. measured peripheral pressure waveform. Each of this correlation curves were fitted to linear, quadratic and cubic polynomial equation. Wiener model is then simulated for aortic-to-radial artery as well as aortic-to-femoral artery to reconstruct radial and femoral pressure waveform. It was found that Wiener model with 3rd order polynomial function yielded better modeling accuracy (with average RMSE = 2.187 mmHg for radial and 4.281 mmHg for femoral pressure) than that from 2nd order polynomial function (with average RMSE = 2.242 mmHg for radial and 4.355 mmHg for femoral pressure) which in turn was better than mere linear FIR filter (with average RMSE = 2.604 mmHg for radial and 4.810 mmHg for femoral pressure).
Related Concept Videos
Special considerations while measuring pulse
Pulse
The pulse serves as a clinical...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Regulation of Pulse
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....