First simultaneous measurements of Reynolds stress with ball-pen and Langmuir probes
Ondrej Grover1, Jiri Adamek2, Jakub Seidl2
1Faculty of Nuclear Physics, Czech Technical University in Prague, Prague 115 19, Czech Republic.
Abstract:
A new multi-pin probe head was installed and tested at the COMPASS tokamak. The probe head consists of several ball-pen and Langmuir probes in similar geometric configurations, which enables fast, simultaneous measurements of the radial and poloidal electric field components from differences of plasma or floating potentials using appropriately positioned ball-pen or Langmuir probes, respectively. The fast measurements of the radial electric field are compared with other methods of measuring selected frequency components of the radial electric field. The radial profiles of the Reynolds stress calculated from correlations of electric field fluctuations obtained by either probe type are compared along with their spectral composition. Lower Reynolds stress values are found for Langmuir probes in comparison to ball-pen probes due to negative contributions from higher frequency fluctuations possibly associated with electron temperature fluctuations.