Comparative Evaluation of 2-Hour Rapid Diagnostic Algorithms for Acute Myocardial Infarction Using High-Sensitivity
Andrew D McRae1, Grant Innes1, Michelle Graham2
1Department of Emergency Medicine, University of Calgary, Calgary, Alberta, Canada; Department of Community Health Sciences, University of Calgary, Calgary, Alberta, Canada.
Background:
Symptoms of acute coronary syndrome account for a large proportion of emergency department (ED) visits and hospitalizations. High-sensitivity troponin can rapidly rule out or rule in acute myocardial infarction (AMI) within a short time of ED arrival. We sought to validate test characteristics and classification performance of 2-hour high-sensitivity troponin T (hsTnT) algorithms for the rapid diagnosis of AMI.
Methods:
We included consecutive patients from 4 academic EDs with suspected cardiac chest pain who had hsTnT assays performed 2 hours apart (± 30 minutes) as part of routine care. The primary outcome was AMI at 7 days. Secondary outcomes included major adverse cardiac events (mortality, AMI, and revascularization). Test characteristics and classification performance for multiple 2-hour algorithms were quantified.
Results:
Seven hundred twenty-two patients met inclusion criteria. Seven-day AMI incidence was 10.9% and major adverse cardiac event incidence was 13.7%. A 2-hour rule-out algorithm proposed by Reichlin and colleagues ruled out AMI in 59.4% of patients with 98.7% sensitivity and 99.8% negative predictive value (NPV). The 2-hour rule-out algorithm proposed by the United Kingdom National Institute for Health and Care Excellence ruled out AMI in 50.3% of patients with similar sensitivity and NPV. Other exploratory algorithms had similar sensitivity but marginally better classification performance. According to Reichlin et al., the 2-hour rule-in algorithm ruled in AMI in 16.5% of patients with 92.4% specificity and 58.5% positive predictive value.
Conclusions:
Two-hour hsTnT algorithms can rule out AMI with very high sensitivity and NPV. The algorithm developed by Reichlin et al. had superior classification performance. Reichlin and colleagues' 2-hour rule-in algorithm had poor positive predictive value and might not be suitable for early rule-in decision-making.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
11:17A Microscopic 2,3,5-Triphenyltetrazolium Chloride Assay for Accurate and Reliable Analysis of Myocardial Injury
Published on: November 28, 2025
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome I: Introduction
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Myocarditis II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System V: CT