Related Experiment Video
Updated: Feb 27, 2026

Author Spotlight: Technologies and Challenges in Elemental Analysis of Food Samples
Published on: December 22, 2023
Microwave-Induced Plasma Optical Emission Spectrometry (MIP OES) and Standard Dilution Analysis to Determine Trace
Amanda G Althoff1, Charles B Williams1, Tina McSweeney2
11 Department of Chemistry, Wake Forest University, Salem Hall, Winston-Salem, NC, USA.
Abstract:
In this work, we evaluate the application of microwave-induced plasma optical emission spectrometry (MIP OES) to determine of Al, Cr, Co, Cu, Fe, Mn, Ni and Zn in children's cough syrup, eye drops, and oral antiseptic using standard dilution analysis (SDA). The SDA method is simple, with only two calibration solutions prepared per sample. The first solution (S1), composed of 50% sample +50% of a standard solution, is introduced into the plasma and the analytical signals are monitored in a time-resolved fashion. Then, the second solution (S2), composed of 50% sample +50% blank, is poured into the vial containing S1. As the solutions mix, the analytical signals gradually drop to a stable baseline. The calibration curve is computed by plotting the ratio of the analyte signal (SA) over the internal standard signal (which is also part of S1) (SIS) on the y-axis, versus the inverse of the IS concentration on the x-axis (i.e., SA/SIS versus 1/CIS). In this study, SDA results were compared with values obtained with the traditional methods of external calibration (EC), internal standardization (IS), and standard additions (SA) in MIP OES determinations. The precision (represented as percent RSD) for SDA showed values in the range of 2.50-8.00% for all samples, while conventional calibration methods showed RSDs in the range of 6.40-32.50% for EC, 8.30-21.80% for IS, and 5.20-17.40% for SA. The LODs calculated for SDA are below the maximum limits allowed by the major pharmaceutical regulatory agencies, and presents superior precision and accuracy compared to the traditional calibration methods. Considering its simplicity and efficiency, SDA is an important new tool for accurate analyses of pharmaceuticals.
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Emission Spectroscopy: Interference

