An Analysis of Substandard Propofol Detected in Use in Zambian Anesthesia
Hazel Mumphansha1, Jason W Nickerson, Amir Attaran
1From the *Department of Anaesthesia, University Teaching Hospital, Lusaka, Zambia; †Bruyère Research Institute, Ottawa, Ontario, Canada; ‡Faculty of Law, University of Ottawa, Ottawa, Ontario, Canada; §John L. Holmes Mass Spectrometry Facility, Department of Chemistry and Biomolecular Sciences, University of Ottawa, Ottawa, Canada; and ‖Anesthesiology and Pain Medicine, Children's Hospital of Eastern Ontario, University of Ottawa, Ottawa, Canada.
Background:
In early 2015, clinicians throughout Zambia noted a range of unpredictable adverse events after the administration of propofol, including urticaria, bronchospasm, profound hypotension, and most predictably an inadequate depth of anesthesia. Suspecting that the propofol itself may have been substandard, samples were procured and sent for testing.
Methods:
Three vials from 2 different batches were analyzed using gas chromatography-mass spectrometry methods at the John L. Holmes Mass Spectrometry Facility.
Results:
Laboratory gas chromatography-mass spectrometry analysis determined that, although all vials contained propofol, its concentration differed between samples and in all cases was well below the stated quantity. Two vials from 1 batch contained only 44% ± 11% and 54% ± 12% of the stated quantity, whereas the third vial from a second batch contained only 57% ± 9%. The analysis found that there were no hexane-soluble impurities in the samples.
Conclusions:
None of the analyzed vials contained the stated amount of propofol; however, our analysis did not detect additional contaminants that would explain the adverse events reported by clinicians. Our results confirm the presence of substandard propofol in Zambia; however, anecdotal accounts of substandard anesthetic medicines in other countries abound and warrant further investigation to provide estimates of the prevalence and scope of this global problem.
Insights
Substandard propofol was identified in Zambia, with samples containing significantly less active ingredient than stated. This confirms concerns about drug quality and warrants further global investigation into anesthetic medicine safety.
Area of Science:
- Anesthesiology
- Pharmacology
- Analytical Chemistry
Background:
- Clinicians in Zambia reported adverse events linked to propofol administration in early 2015.
- Suspicions arose regarding the quality of propofol, prompting sample procurement for analysis.
Purpose of the Study:
- To investigate the quality and concentration of propofol samples used in Zambia.
- To determine if propofol quality issues could explain reported adverse events.
Main Methods:
- Three propofol vials from two different batches were analyzed.
- Gas chromatography-mass spectrometry (GC-MS) was employed for quantitative and impurity analysis.
Main Results:
- All analyzed vials contained propofol, but concentrations were significantly below the stated quantity.
- Concentrations ranged from 44% to 57% of the labeled amount.
- No hexane-soluble impurities were detected in the samples.
Conclusions:
- The study confirmed the presence of substandard propofol in Zambia.
- While contaminants were not identified as the cause of adverse events, the low propofol concentration is a critical finding.
- Further global research is recommended to assess the prevalence of substandard anesthetic medicines.