Relevance of Bolus Calculators in Current Hybrid Closed Loop Systems
1Barbara Davis Center, University of Colorado Denver , Aurora, Colorado.
Diabetes Technology & Therapeutics
|July 8, 2017
Abstract
No abstract available in PubMed .
Related Concept Videos
Open and closed-loop control systems
1.8K
Control systems are foundational elements in automation and engineering. They are broadly categorized into open-loop and closed-loop systems. These classifications hinge on the presence or absence of feedback mechanisms, significantly influencing the system's performance, complexity, and application.
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
1.8K
One-Compartment Open Model for IV Bolus Administration: General Considerations
838
The one-compartment model is a pharmacokinetic tool that models the body as a single, uniform compartment, facilitating the understanding of drug distribution and elimination. This model is particularly beneficial for intravenous (IV) bolus administration, where the drug rapidly circulates throughout the body.
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
838
Two-Compartment Open Model: IV Bolus Administration
1.2K
The two-compartment model for intravenous (IV) bolus administration illustrates drug distribution in the body, subdividing it into central and peripheral compartments. This model operates on the concept of two-compartment kinetics. The drug's plasma concentration shows a bi-exponential decline following IV bolus administration, signaling the presence of two disposition processes: distribution and elimination.
The disparity between drug input and the sum of drug transfer rates between...
The disparity between drug input and the sum of drug transfer rates between...
1.2K
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
417
Clearance is a key pharmacokinetic parameter that quantifies the volume of body fluid from which a drug is entirely removed within a specific time frame. It is crucial in assessing how a drug is eliminated from the body and has critical clinical applications.
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
417
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
992
The one-compartment open model is a simplified approach used in pharmacokinetics to understand the distribution and elimination of a drug administered through an intravenous bolus. This model assumes rapid drug dispersal throughout the body and elimination using a first-order process. Key pharmacokinetic parameters, such as the elimination rate constant (k), half-life (t1/2), and the apparent volume of distribution (Vd), can be estimated from this model. The elimination rate is calculated...
992
Control System Problem
461
In an open-loop system, such as a basic thermostat, the poles of the transfer function influence the system's response but do not determine its stability. However, when feedback is introduced to form a closed-loop system, such as an advanced thermostat that adjusts heating based on room temperature, stability is governed by the new poles of the closed-loop transfer function.
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
461