Related Experiment Video
Updated: Feb 27, 2026

Formation of Dispersible Taohong Siwu Tablets
Published on: February 3, 2023
Solid state characterisation and taste masking efficiency evaluation of polymer based extrudates of isoniazid for
Alison V Keating1, Jessica Soto2, Catherine Tuleu1
1UCL School of Pharmacy, 29-39 Brunswick Square, London, WC1N 1AX, UK.
Abstract:
Hot melt extrusion has gained considerable attention as a novel technique for taste masking of bitter APIs. The aim of this study was to investigate whether hot melt extrusion could be used to develop taste masked formulations of isoniazid and also to evaluate and correlate different taste assessment methods Two polymers with different physico-chemical properties, Soluplus and Eudragit E-PO were chosen as carriers for the drug. Eudragit E-PO has already been widely used for taste masking due to its selective release properties, while Soluplus has not been studied in this regard but provides a useful comparator of a polymer that should release the drug reasonably efficiently. Polymeric formulations of isoniazid were produced with drug loadings of 20% and 30% w/w. The solid state characteristics of the formulations were assessed by differential scanning calorimetry and powder X-ray diffraction. The taste of isoniazid was assessed using the rodent Brief Access Taste Aversion (BATA) model, while formulations were assessed using the electronic tongue and dissolution under simulated oral conditions. Investigation into the drug loading effect with these two polymers showed that all Soluplus based extrudates with drug loading up to 30% w/w were fully amorphous while Eudragit E-PO based extrudates contained crystalline drug as demonstrated by both DSC and PXRD, dependent on loading. BATA testing of isoniazid gave an IC50 value, i.e. the dose of drug which inhibits 50% of licks, of 11.1mg/mL. Taste assessment of the formulations using both simulated oral drug release and the electronic tongue demonstrated that Eudragit E-PO based formulations had a better taste masking efficiency than Soluplus. This is due to the fact that significantly less isoniazid is released from the Eudragit E-PO based formulations under oral conditions.
More Related Videos
04:59Author Spotlight: Developing a Disposable Dosator for Preclinical Testing of Dry Powder Inhalers in Small Animal Models
Published on: August 18, 2023
10:10Transport Properties of Ibuprofen Encapsulated in Cyclodextrin Nanosponge Hydrogels: A Proton HR-MAS NMR Spectroscopy Study
Published on: August 15, 2016
Related Concept Videos
Pharmaceutical Alternatives: Polymorphic Form-Related and Particle Size-Related Therapeutic Nonequivalence
Factors Influencing Drug Absorption: Pharmaceutical Parameters
Factors Affecting Dissolution: Polymorphism, Amorphism and Pseudopolymorphism
Some polymorphic crystals possess lower aqueous solubility than their amorphous counterparts, leading to incomplete absorption. For instance, the oral suspension of Chloramphenicol, which...
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules
Bioavailability Enhancement: Drug Stability Enhancement and GI Retention
Factors Influencing Drug Absorption: Physicochemical Parameters
Enhanced drug absorption can be achieved by reducing particle sizes and increasing surface areas, thereby facilitating...