Analysis of Hemodynamic Changes in Early Stage after Carotid Stenting by Transcranial Doppler-A Preliminary Study

Ziguang Yan1, Min Yang1, Guochen Niu1

  • 1Department of Interventional Radiology and Vascular Surgery, Peking University First Hospital, Beijing, China.

Insights

Carotid artery stenting (CAS) can increase blood flow in the ipsilateral middle cerebral artery (MCA) within 4 hours. This study used transcranial Doppler (TCD) to evaluate these early hemodynamic changes after CAS.

Area of Science:

  • Neuroscience
  • Vascular Surgery
  • Medical Imaging

Background:

  • Cerebral hyperperfusion syndrome and hemodynamic instability are known risks post-carotid artery stenting (CAS).
  • Early hemodynamic changes within 6 hours after CAS are not well understood.
  • This study investigates early cerebral hemodynamic changes following CAS using transcranial Doppler (TCD).

Purpose of the Study:

  • To evaluate early post-procedure cerebral hemodynamic changes after carotid artery stenting (CAS).
  • To assess changes in middle cerebral artery (MCA) peak systolic velocity (PSV) and pulsatility index (PI) using TCD within 4 hours post-CAS.

Main Methods:

  • Retrospective review of 61 patients undergoing CAS from January 2013 to July 2014.
  • TCD examinations performed on 44 patients before CAS and at 1-2 and 3-4 hours after CAS.
  • Measurement of MCA PSV and PI on ipsilateral and contralateral sides, along with blood pressure monitoring.

Main Results:

  • A significant increase in ipsilateral MCA PSV was observed 1-2 hours (19.9% increase) and 3-4 hours (18.2% increase) post-CAS.
  • No significant difference in MCA PSV was found between the 1-2 hour and 3-4 hour post-CAS intervals.
  • The pulsatility index (PI) in the ipsilateral MCA also showed a significant increase within 4 hours post-CAS.
  • No significant MCA PSV increase was detected on the contralateral side.

Conclusions:

  • Carotid artery stenting (CAS) can lead to significant increases in ipsilateral MCA PSV and PI within 4 hours.
  • The observed increase in MCA PSV was significantly greater on the ipsilateral compared to the contralateral side.
  • MCA PSV remained stable between 1-2 hours and 3-4 hours post-CAS.