Related Experiment Video
Updated: Feb 27, 2026

Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping
Published on: February 22, 2018
Tachycardia-Induced J-Wave Changes in Patients With and Without Idiopathic Ventricular Fibrillation
Yoshiyasu Aizawa1, Seiji Takatsuki2, Takahiko Nishiyama2
1From the Department of Cardiology, Keio University School of Medicine, Tokyo, Japan (Y.A., S.T., T.N., T.K., S.K., K.F.); Department of Cardiovascular Medicine Gunma University Graduate School of Medicine, Japan (Y.K.); Department of Cardiology, Nagoya University Graduate School of Medicine, Japan (Y.I.); Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Japan (N.T.); Division of Arrhythmia and Electrophysiology, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, Osaka, Japan (S.N.); and Division of Research and Development, Tachikawa Medical Center, Niigata, Japan (Y.A.). yoshiyaaizawa-circ@umin.ac.jp.
Background:
To know the underlying mechanisms of J waves, the response to atrial pacing was studied in patients with idiopathic ventricular fibrillation (IVF) and patients with non-IVF.
Methods And Results:
In 8 patients with IVF, the J-wave amplitude was measured before, during, and after atrial pacing. All patients had episodes of ventricular fibrillation without structural heart disease. The responses of J waves were compared with those of the 17 non-IVF control subjects who revealed J waves but no history of cardiac arrest and underwent electrophysiological study. The IVF patients were younger than the non-IVF patients (28±10 versus 52±14 years, respectively; P=0.002) and had larger J waves with more extensive distribution. J waves decreased from 0.35±0.26 to 0.22±0.23 mV (P=0.025) when the RR intervals were shortened from 782±88 to 573±162 ms (P=0.001). A decrease (≥0.05 mV) in the J-wave amplitude was observed in 6 of the 8 patients. In addition, 1 patient showed a distinct reduction of J waves in the unipolar epicardial leads. In contrast, J waves were augmented in the 17 non-IVF subjects from 0.27±0.09 to 0.38±0.10 mV (P<0.001): augmented in 9 and unchanged in the 8 subjects. The different response patterns of J waves to rapid pacing suggest different mechanisms: early repolarization in IVF patients and conduction delay in non-IVF patients.
Conclusions:
The response to atrial pacing was different between the IVF and non-IVF patients, which suggests the presence of different mechanisms for the genesis of J waves.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
09:17High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Related Concept Videos
Dysrhythmias III: Characteristics of Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias II: Classification of Tachyarrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Increased pulse rate
Many factors can elevate the risk of developing tachycardia. These include advanced age, a family history of arrhythmias, and an...