Image improvement method for positron emission mammography
Nikolai V Slavine1, Stephen J Seiler2, Roderick W McColl3
1Translational Research, Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-9061, USA.
Purpose:
To evaluate in clinical use a rapidly converging, efficient iterative deconvolution algorithm (RSEMD) for improving the quantitative accuracy of previously reconstructed breast images by a commercial positron emission mammography (PEM) scanner.
Materials And Methods:
The RSEMD method was tested on imaging data from clinical Naviscan Flex Solo II PEM scanner. This method was applied to anthropomorphic like breast phantom data and patient breast images previously reconstructed with Naviscan software to determine improvements in image resolution, signal to noise ratio (SNR) and contrast to noise ratio (CNR).
Results:
In all of the patients' breast studies the improved images proved to have higher resolution, contrast and lower noise as compared with images reconstructed by conventional methods. In general, the values of CNR reached a plateau at an average of 6 iterations with an average improvement factor of about 2 for post-reconstructed Flex Solo II PEM images. Improvements in image resolution after the application of RSEMD have also been demonstrated.
Conclusions:
A rapidly converging, iterative deconvolution algorithm with a resolution subsets-based approach (RSEMD) that operates on patient DICOM images has been used for quantitative improvement in breast imaging. The RSEMD method can be applied to PEM images to enhance the resolution and contrast in cancer diagnosis to monitor the tumor progression at the earliest stages.
More Related Videos
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...