Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Positron Emission Tomography01:29

Positron Emission Tomography

7.8K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
7.8K
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

668
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
668
Radiological Investigation III: Pulmonary Angiogram and PET Scan01:13

Radiological Investigation III: Pulmonary Angiogram and PET Scan

531
Radiological investigations are paramount in the diagnosis and management of various pulmonary diseases. Two essential investigations are the Pulmonary Angiogram and the Positron Emission Tomography (PET) Scan.
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
531

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Time-resolved GluCEST MRI of acute glutamate-related signal changes following kainic acid administration.

Journal of the neurological sciences·2026
Same author

Letter to the editor: "Precipitation of gadolinium from magnetic resonance imaging contrast agents may be the Brass tasks of toxicity".

Magnetic resonance imaging·2026
Same author

Extramammary metastases to the breast: Radiologic and histologic review.

Clinical imaging·2025
Same author

Editorial for "Assessing the Diagnostic Value of MRI T1rho Mapping in Predicting Molecular Prognostic Biomarkers and Subtypes of Breast Cancer".

Journal of magnetic resonance imaging : JMRI·2025
Same author

Evaluation of renal masses with CEST MRI: Protocol optimization and preliminary results.

Magnetic resonance in medicine·2025
Same author

For the busy clinical-imaging professional in an AI world: Gaining intuition about deep learning without math.

Journal of medical imaging and radiation sciences·2024
Same journal

Proton RBE for in vivo model systems: LET and dose dependencies for early and late biological endpoints.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2026
Same journal

AI-augmented thyroid scintigraphy for robust classification of disease.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2026
Same journal

Updating national diagnostic reference levels for adult cardiac interventional procedures in Switzerland.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2026
Same journal

Adoption of AI-driven automation and adaptive radiotherapy in clinical practice: results from a national survey.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2026
Same journal

Sivan Unit (SU) for standardization of voxel intensity in CBCT: A multi-vendor, multi-centric validation study.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2026
Same journal

VIT-MBRT, a GPU accelerated Monte Carlo tool for investigations on preclinical minibeam radiation therapy.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2026
See all related articles

Related Experiment Video

Updated: Feb 27, 2026

Positron Emission Tomography Imaging for In Vivo Measuring of Myelin Content in the Lysolecithin Rat Model of Multiple Sclerosis
08:40

Positron Emission Tomography Imaging for In Vivo Measuring of Myelin Content in the Lysolecithin Rat Model of Multiple Sclerosis

Published on: February 28, 2021

4.5K

Image improvement method for positron emission mammography.

Nikolai V Slavine1, Stephen J Seiler2, Roderick W McColl3

  • 1Translational Research, Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-9061, USA.

Physica Medica : PM : an International Journal Devoted to the Applications of Physics to Medicine and Biology : Official Journal of the Italian Association of Biomedical Physics (AIFB)
|July 10, 2017
PubMed
Summary
This summary is machine-generated.

This study evaluates a new computational method called RSEMD designed to sharpen and clarify breast images produced by specialized PET scanners. By refining existing image data, this technique improves the visibility of small details and enhances contrast, potentially helping clinicians detect and monitor breast cancer more accurately.

Keywords:
Image resolution improvementPositron emission mammography (PEM)Resolution subsets-based iterative methodSNR and CNR improvementdiagnostic imagingbreast cancer screeningdeconvolution algorithmquantitative accuracy

Frequently Asked Questions

More Related Videos

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
14:19

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space

Published on: February 1, 2016

9.0K
Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
09:21

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images

Published on: February 18, 2015

12.7K

Related Experiment Videos

Last Updated: Feb 27, 2026

Positron Emission Tomography Imaging for In Vivo Measuring of Myelin Content in the Lysolecithin Rat Model of Multiple Sclerosis
08:40

Positron Emission Tomography Imaging for In Vivo Measuring of Myelin Content in the Lysolecithin Rat Model of Multiple Sclerosis

Published on: February 28, 2021

4.5K
A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
14:19

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space

Published on: February 1, 2016

9.0K
Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
09:21

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images

Published on: February 18, 2015

12.7K

Area of Science:

  • Medical imaging physics within Positron Emission Mammography research
  • Diagnostic radiology and oncology informatics

Background:

Current breast imaging techniques often struggle to provide the high-resolution detail required for early cancer detection. Clinicians frequently face challenges when interpreting scans that lack sufficient clarity for precise diagnosis. Prior research has shown that standard reconstruction software may limit the diagnostic utility of captured data. That uncertainty drove the development of advanced post-processing tools to refine existing images. No prior work had resolved the specific limitations of commercial scanners using this particular iterative approach. This gap motivated the current evaluation of a novel deconvolution algorithm. Investigators sought to determine if this method could enhance quantitative metrics in a clinical setting. The study addresses the need for improved image quality without requiring new hardware acquisitions.

Purpose Of The Study:

The study aims to evaluate the clinical utility of a rapidly converging iterative deconvolution algorithm for breast imaging. Researchers sought to improve the quantitative accuracy of images produced by commercial scanners. The team addressed the limitations of standard reconstruction software currently used in clinical practice. This investigation focuses on enhancing image resolution, signal-to-noise ratios, and contrast-to-noise ratios. By applying this method to existing data, the authors intended to demonstrate a practical path for image refinement. The motivation stems from the need for clearer visualizations to support early cancer diagnosis. Investigators examined whether this algorithm could reliably process patient breast images and phantom data. The work establishes a framework for optimizing diagnostic outputs without modifying the underlying hardware.

Main Methods:

The review approach involved testing a resolution subsets-based iterative deconvolution algorithm on existing clinical data. Investigators processed images originally generated by standard commercial software. The team utilized both anthropomorphic breast phantoms and actual patient scans for validation. This computational design allowed for a direct comparison between conventional results and the refined outputs. Researchers applied the algorithm to Digital Imaging and Communications in Medicine files to ensure compatibility. The study focused on quantifying changes in resolution, signal-to-noise ratio, and contrast-to-noise ratio. By systematically varying the number of iterations, the team identified the optimal convergence point. This methodology provided a rigorous assessment of the algorithm's performance in a clinical environment.

Main Results:

Key findings from the literature demonstrate that the RSEMD method consistently yields superior image quality. All patient studies showed higher resolution and contrast alongside reduced noise levels compared to standard techniques. The contrast-to-noise ratio reached a stable plateau after an average of six iterations. This specific level of processing resulted in an average improvement factor of approximately two for the scanned images. The algorithm successfully enhanced the clarity of previously reconstructed breast data. These quantitative gains were observed across both phantom simulations and clinical patient cases. The results confirm that the deconvolution approach effectively sharpens the final diagnostic output. No other reconstruction method tested provided equivalent improvements in these specific quantitative metrics.

Conclusions:

The authors propose that this deconvolution method effectively enhances the diagnostic quality of breast scans. Synthesis and implications suggest that applying this algorithm to existing data improves resolution and contrast. Researchers observed that signal metrics reached optimal levels after approximately six iterations. This approach offers a practical way to refine images from standard commercial equipment. The findings indicate that clinicians may better monitor tumor progression through these clearer visualizations. The study demonstrates that quantitative accuracy increases significantly following the application of this technique. These results support the integration of such algorithms into routine breast imaging workflows. Future clinical utility appears promising for detecting abnormalities at their earliest stages of development.

The researchers propose that the RSEMD algorithm improves quantitative accuracy by refining previously reconstructed images. This iterative deconvolution process enhances resolution, signal-to-noise ratios, and contrast-to-noise ratios compared to conventional reconstruction techniques.

The study utilized the Naviscan Flex Solo II PEM scanner to acquire clinical imaging data. This specific hardware provided the raw inputs for the deconvolution process, which was then applied to both anthropomorphic breast phantoms and actual patient breast images.

The authors state that the RSEMD method operates on Digital Imaging and Communications in Medicine (DICOM) files. This data format is necessary because the algorithm performs post-reconstruction processing on images already generated by standard commercial software.

The researchers employed both anthropomorphic breast phantoms and patient breast images. These data types allowed the team to validate the algorithm's performance in controlled, simulated environments before confirming its effectiveness in real-world clinical breast studies.

The team measured improvements in image resolution, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). They observed that CNR values reached a plateau at an average of six iterations, yielding an average improvement factor of approximately two.

The researchers propose that this method enhances resolution and contrast to assist in cancer diagnosis. They suggest that these improvements allow clinicians to monitor tumor progression more effectively, particularly during the earliest stages of the disease.