A new mathematical model of wrist pulse waveforms characterizes patients with cardiovascular disease - A pilot study
Dianning He1, Lu Wang2, Xiaobing Fan3
1Sino-Dutch Biomedical and Information Engineering School, Northeastern University, Shenyang, Liaoning 110819, China ; Department of Radiology, The University of Chicago, Chicago, IL 60637, USA.
Abstract:
The purpose of this study was to analyze and compare a series of measured radial pulse waves as a function of contact pressure for young and old healthy volunteers, and old patients with cardiovascular disease. The radial pulse waves were detected with a pressure sensor and the contact pressure of the sensor was incremented by 20gf during the signal acquisition. A mathematical model of radial pulse waveform was developed by using two Gaussian functions modulated by radical functions and used to fit the pulse waveforms. Then, a ratio of area (rA) and a ratio of peak height (rPH) between percussion wave and dicrotic wave as a function of contact pressure were calculated based on fitted parameters. The results demonstrated that there was a maximum for waveform peak height, a minimum for rA (rAmin) and a minimum for rPH (rPHmin) appeared as contact pressure varied. On average, older patients had higher peak amplitude and a significantly smaller rAmin (p<0.001) and rPHmin (p<0.02) than the young and old volunteers. The rAmin and rPHmin calculated with the mathematical model had moderate to strong positive linear correlations (r=0.66 to 0.84, p<0.006) with those directly calculated without the model. The receiver operating characteristic (ROC) analysis showed that the rAmin calculated with the model and the contact pressure measured at the rAmin had good diagnostic accuracy to distinguish healthy volunteers vs. diseased patients. Therefore, using the mathematical model to quantitatively analyze the radial pulse waveforms as a function of contact pressure could be useful in the diagnosis of cardiovascular diseases.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse
The pulse serves as a clinical...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Special considerations while measuring pulse