Related Experiment Video
Updated: Feb 27, 2026

Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Use of warm carbon dioxide insufflators does not affect intra-colonic gas temperature and has no effect on polyp
Akash M Patel1, Jordan Green1, Fahd Jowhari1
1Gastrointestinal Diseases Research Unit, Department of Medicine, Queen's University, Kingston, Ontario.
Background And Study Aims:
Methods to improve polyp detection during colonoscopy have been investigated, with conflicting results for warm water irrigation. Carbon Dioxide (CO 2) warmed to 37 °C may have similar or more pronounced effects on bowel motility. This study aimed to assess whether warmed CO 2 would improve polyp detection compared to room temperature air insufflation.
Patients And Methods:
This was a double-blind, randomized controlled trial that enrolled 204 patients undergoing screening or surveillance outpatient colonoscopy. The primary outcome was polyp per patient detection rate. Secondary outcomes included adenoma per patient detection rates, bowel spasm, and patient comfort.
Results:
The trial was terminated after an interim analysis determined futility. Between the warmed CO 2 and room air groups, no significant differences were found in the per-colonoscopy polyp detection rate ( P = 0.57); overall polyp detection rate ( P = 0.69); or adenoma detection rates ( P = 0.74). More patients in the room temperature group had lower spasm scores (p = 0.02); however, there was a trend towards greater patient comfort in the warmed CO 2 group ( P = 0.054). An ex-vivo study showed a significant difference between exiting CO 2 temperature at the insufflator end vs. delivered CO 2 temperature at the colonoscope tip end. The temperature of insufflation at the tip of the colonoscope was not different when using warmed vs. unwarmed insufflation ( P = 0.62).
Conclusion:
When compared with room air insufflation, warmed CO 2 insufflation did not affect polyp detection rates.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures II: Colonoscopy
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...

