Related Experiment Video
Updated: Feb 26, 2026

Immunoglobulin Gene Sequence Analysis In Chronic Lymphocytic Leukemia: From Patient Material To Sequence Interpretation
Published on: November 26, 2018
Heavy + light chain analysis to assign myeloma response is analogous to the IMWG response criteria
Guillemette Fouquet1, Kym Ie Snell2, Stéphanie Guidez3
1a Hôpital Huriez, CHU , Lille , France.
Automated serum heavy + light chain (HLC) immunoassays can measure the intact immunoglobulins of each light chain type separately. We though to compare HLC assays with electrophoretic techniques in determining International Myeloma Working Group (IMWG) response criteria. 114 myeloma patients from 2 trials were included. HLC measurements were made utilizing archived sera and response assessments compared with those based on electrophoretic analysis at the time of the trials. Assessments at ∼90 days and maximal response were compared as was the power of the 2 techniques for predicting later responses, overall survival, and progression. The kappa statistic indicated good agreement between the 2 methods for determining IMWG response criteria, although HLC measurements might give better predictions of subsequent responses and frequently gave an earlier indication of change. HLC measurements could represent an alternative to electrophoretic techniques in determining IMWG response. Validation with a greater range of patient responses is needed for confirmation.
Automated serum heavy + light chain (HLC) immunoassays can measure the intact immunoglobulins of each light chain type separately. We though to compare HLC assays with electrophoretic techniques in determining International Myeloma Working Group (IMWG) response criteria. 114 myeloma patients from 2 trials were included. HLC measurements were made utilizing archived sera and response assessments compared with those based on electrophoretic analysis at the time of the trials. Assessments at ∼90 days and maximal response were compared as was the power of the 2 techniques for predicting later responses, overall survival, and progression. The kappa statistic indicated good agreement between the 2 methods for determining IMWG response criteria, although HLC measurements might give better predictions of subsequent responses and frequently gave an earlier indication of change. HLC measurements could represent an alternative to electrophoretic techniques in determining IMWG response. Validation with a greater range of patient responses is needed for confirmation.

