Related Experiment Video
Updated: Feb 26, 2026

Murine Model of Central Venous Stenosis using Aortocaval Fistula with an Outflow Stenosis
Published on: July 11, 2019
[Intravascular Hemolysis Caused by Stenosis of an Elephant Trunk;Report of a Case]
Rikako Takamaru1, Koji Kawahito, Kei Aizawa
1Department of Cardiothoracic Surgery, Jichi Medical University, Tochigi, Japan.
Abstract:
Symptomatic intravascular hemolysis after prosthetic aortic graft replacement is rare. It is primarily attributed to mechanical injury of red blood cells caused by stenosis of the vascular graft. A 50-year-old man presented with hemolytic anemia, 5 years after total arch replacement with an elephant trunk for type A aortic dissection. The hemolysis was caused by graft stenosis of the elephant trunk. Endovascular treatment for the stenotic elephant trunk was successfully performed. The postoperative course was uneventful, and the hemolysis was resolved immediately after operation.