Related Experiment Video
Updated: Jan 26, 2026

Surgery and Behavioral Testing in the Tibial Neuroma Transposition Model in Rats
Published on: January 6, 2023
Asymmetric Tibial Component Improved the Coverage and Rotation of the Tibial Component in a Medial Pivot Total Knee
Yukihide Minoda1, Mitsuhiko Ikebuchi1, Shigekazu Mizokawa1
1Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan.
Abstract:
Malrotation of tibial components is one of the important causes of failure in total knee arthroplasty. The aim of this study is to determine the relationship between tibial rotational positioning and coverage of the tibial surface during the operation, using a symmetric and newly introduced asymmetric medial pivot tibial components. The coverage and overhang were compared between a symmetric component (Advance medial pivot) and a newly introduced asymmetric medial pivot tibial component (Evolution medial pivot) in 31 knees during the operation. When the tibial component was placed parallel to the anteroposterior (AP) axis, the uncovered width in the posteromedial part using a symmetric design was larger than that using an asymmetric design (p < 0.01). Overhang in the posterolateral part was observed in 42% for a symmetric design and 3% for an asymmetric design (p < 0.01). When the component was placed in malrotation (10 degrees internal to the AP axis), overhang in the posteromedial part was observed in 6% for a symmetric design and in 71% for an asymmetric design (p < 0.01). The tibial rotation parallel to the AP axis and maximizing coverage of the tibial surface conflict in a symmetric design, but are compatible in an asymmetric design. An asymmetric tibial component is expected to improve the coverage and the rotational positioning of medial pivot total knee prosthesis.
Related Concept Videos
Rotation of Asymmetric Top
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...
Components of Stress
Interestingly, the hidden cube faces also experience these stresses, equal and...
Components of Language
Curvilinear Motion: Rectangular Components
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the...
Drug Binding to Blood Components
HSA is the most abundant plasma protein and is vital in drug binding. It contains distinct drug-binding sites, with different drugs exhibiting affinity for specific sites. There are three main drug-binding domains for HSA: sites I, II, and III. These domains are...
Vector Algebra: Method of Components
In many applications, the magnitudes and directions of...