Related Experiment Video
Updated: Feb 26, 2026

A Novel Capsulorhexis Technique Using Shearing Forces with Cystotome
Published on: May 15, 2010
A Novel Method for the Management of Anophthalmic Socket
Srinivasa B Rao1, Savita Akki2, Deepak Kumar3
1Department of Maxillofacial Prosthodontics and Implantology, Gitams Dental College, Visakhapatnam, Andhra Pradesh, India.
Abstract:
An orbital defect causes severe facial asymmetry and disfigurement that result in an immense emotional trauma to the patient and is also associated with economic, esthetic, and psychological problems. A prosthetic replacement is the treatment of choice in helping individual to return to his normal life by producing an acceptable and lifelike appearance. This case report describes the critical areas of fabrication of ocular prosthesis for a patient with missing right eye due to trauma to eye ball in an accident. Patient had given a history of surgical enucleation of the eye 15 days after ocular trauma. A polymethyl methacrylate ocular prosthesis was planned. The technique described in this case report presents the use of both custom-made and stock eye shell in an attempt to include the benefits of both. A novel attempt was made to simulate eye movements and exact color matching to that of contralateral eye to provide a better and functional ocular prosthesis to the patient.