Complex decorrelation averaging in optical coherence tomography: a way to reduce the effect of multiple scattering
Abstract:
We demonstrate that complex decorrelation averaging can reduce the effect of multiple scattering and improve optical coherence tomography (OCT) imaging contrast. Complex decorrelation averaging calculates the product of an A-scan and the complex conjugate of a subsequent A-scan. The resultant signal is the product of the amplitudes and the phase difference. All these resulting complex signals at a particular location are then averaged. We take advantage of the fact that complex averaging, in contrast to conventional magnitude averaging, is sensitive to phase decorrelation. Sample motion that increases signal phase variance results in lower signal magnitude after complex averaging. Such motion preferentially results in a faster decorrelation of the multiple scattering signal when compared to the single scattering signal with each scattering event spreading the phase. This indicates that we may reduce multiple scattering by implementing complex decorrelation averaging to preferentially reduce the magnitude of the multiply scattered light signal in OCT images. By adjusting the time between phase-differenced A-scans, one can regulate the amount of measured decorrelation. We have performed experiments on liquid phantoms that give experimental evidence for this hypothesis. A substantial improvement in OCT image contrast using complex decorrelation averaging is demonstrated.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...