Related Experiment Video
Updated: Feb 26, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Response surface methodology based on central composite design accompanied by multivariate curve resolution to model
Mohammadreza Taheri1, Mohsen Bagheri1, Roudabeh Sadat Moazeni-Pourasil2
1Medicinal Plants and Drugs Research Institute, Shahid Beheshti University, Tehran, Iran.
Abstract:
Hydrophilic interaction liquid chromatography on bare silica presents some benefits for analysis and purification of ionizable basic alkaloids. This mode was used to separate five major opium alkaloids: morphine, codeine, thebaine, papaverine, and noscapine. Central composite design based on response surface methodology was applied for experimental design, modeling, and optimization in a single-step gradient method. The main effects and their interactions (initial percentage of modifier, changing range of modifier in run time, pH of buffer, and its concentration) were investigated in 30 experiments. Multivariate curve resolution-alternating least squares, by resolving overlapped curves, helped in the accurate calculation of baseline resolution factors to be modeled and optimized more accurately. Then three crucial resolution factors besides elution time were modeled in quadratic and cubic equations and optimized. In addition to the four factors, five extra logarithmic, and nonlogarithmic factors extracted from the four factors to give nine factors overall were inspected on mechanism of retention. It was shown that a linear combination consist of four independence variables successfully describes morphinans retentivity in a single-step gradient method.
More Related Videos
07:29HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Types of Detectors