Measurement of Spatial Stability in Precision Grip
Published on: June 4, 2020
Validating Center-of-Pressure Balance Measurements Using the MatScan® Pressure Mat
Context:
Measurements of center-of-pressure (COP) excursions during balance are common practice in clinical and research settings to evaluate adaptations in postural control due to pathological or environmental conditions. Traditionally measured using laboratory force plates, pressure-mat devices may be a suitable option for clinicians and scientist to measure COP excursions.
Objective:
Compare COP measures and changes during balance between MatScan® pressure mat and force plate.
Design:
Validation study.
Setting:
Laboratory.
Participants:
30 healthy, young adults (19 female, 11 male, 22.7 ± 3.4 y, 70.3 ± SD kg, 1.71 ± 0.09 m).
Main Outcomes:
COP excursions were simultaneously measured using pressure-mat and force-plate devices. Participants completed 3 eyes-open and 3 eyes-closed single-leg balance trials (10 s). Mean of the 3 trials was used to calculate 4 COP variables: medial-lateral and anterior-posterior excursion, total distance, and area with eyes open and eyes closed. Percent change and effect sizes were calculated between eyes-open to eyes-closed conditions for each variable and for both devices.
Results:
All COP variables were highly correlated between devices for eyes-open and eyes-closed conditions (all r > .92, P < .001). Bland-Altman plots suggest the pressure-mat COP measurements were smaller than those of the force-plate, and the differences between devices appeared to increase as the measurement magnitude increased. Percent change in COP variables was highly correlated between devices (r > .85, P < .001). Cohen d effect sizes between eyes-open and eyes-closed were all large (d > 2.25) and similar in magnitude between devices.
Conclusion:
COP measures were correlated between devices, but values tended to be smaller using the pressure mat. The pressure mat and force plate detected comparable magnitude changes in COP measurements between eyes-open and eyes-closed. Pressure mats may provide a viable option for detecting large magnitude changes in postural control during short-duration testing.
More Related Videos
Related Concept Videos
Finding the Center of Gravity
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Significance of Center of Mass
Applications of Integration to Find Centers of Mass
Center of Mass
The knowledge of the center of mass can also help us to describe and predict the motion of objects. For example, when a ball is thrown...
Conservation of Mass in Fixed, Nondeforming Control Volume
In the case of a sewer pipe, which can be modeled...