Related Experiment Video
Updated: Feb 26, 2026

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
Ionophore-Based Titrimetric Detection of Alkali Metal Ions in Serum
Jingying Zhai1, Xiaojiang Xie2, Thomas Cherubini1
1Department of Inorganic and Analytical Chemistry, University of Geneva , Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland.
Abstract:
While the titrimetric assay is one of the most precise analytical techniques available, only a limited list of complexometric chelators is available, as many otherwise promising reagents are not water-soluble. Recent work demonstrated successful titrimetry with ion-exchanging polymeric nanospheres containing hydrophobic complexing agents, so-called ionophores, opening an exciting avenue in this field. However, this method was limited to ionophores of very high affinity to the analyte and exhibited a relatively limited titration capacity. To overcome these two limitations, we report here on solvent based titration reagents. This heterogeneous titration principle is based on the dissolution of all hydrophobic recognition components in a solvent such as dichloromethane (CH2Cl2) where the ionophores are shown to maintain a high affinity to the target ions. HSV (hue, saturation, value) analysis of the images captured with a digital camera provides a convenient and inexpensive way to determine the end point. This approach is combined with an automated titration setup. The titrations of the alkali metals K+, Na+, and Li+ in aqueous solution are successfully demonstrated. The potassium concentration in human serum without pretreatment was precisely and accurately determined as 4.38 mM ± 0.10 mM (automated titration), which compares favorably with atomic emission spectroscopy (4.47 mM ± 0.20 mM).
More Related Videos
11:04Ion Mobility-Mass Spectrometry Techniques for Determining the Structure and Mechanisms of Metal Ion Recognition and Redox Activity of Metal Binding Oligopeptides
Published on: September 7, 2019
12:38Titration ELISA as a Method to Determine the Dissociation Constant of Receptor Ligand Interaction
Published on: February 15, 2018
Related Concept Videos
EDTA: Indirect and Alkalimetric Titration
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Complexometric Titration: Overview
Classification of Titrimetric Analysis Based on Reaction Types
Titrations between an acid and a base lead to neutralization reactions that form...