Related Experiment Video
Updated: Feb 26, 2026

Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
Proposal of a New Index Based on Signal-to-Noise Ratio for Low-contrast Detectability in Computed Tomographic Imaging
Junichi Hashimoto1,2, Shinji Abe2, Yoshiyuki Ishimori2
1Department of Radiology, Tokyo Medical University Ibaraki Medical Center.
Abstract:
The low-contrast detectability of computed tomography (CT) images is commonly evaluated by the contrast-to-noise ratio (CNR) because of its convenience to measure. However, the correlation between CNR and visual detectability is poor because the CNR is a simple index determined by both the contrast of the object and the standard deviation of the image noise. On the other hand, the signal-to-noise ratio (SNR), especially SNR based on the statistical decision theory model (SNRS, D) and SNR based on the matched-filter model (SNRM) are considered superior to CNR. In this study, we investigated a new physical image quality index for evaluating low-contrast detectability (SNRA), which is approximately derived from SNRS, D and SNRM. The new index, which was calculated using the object size, contrast of the object and the noise power spectrum, provided good approximations when the diameter of the rod object was equal and >5 mm. The diameter dependency of the SNRA was also found to provide better sensitivity than the sensitivities of CNR and object-specific CNR, similar to SNRS, D and SNRM. The results suggested that the proposed convenient index should be useful for evaluating the low-contrast detectability of CT images.
More Related Videos
07:013D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...