Related Experiment Video
Updated: Feb 26, 2026

Comprehensive Endovascular and Open Surgical Management of Cerebral Arteriovenous Malformations
Published on: October 20, 2017
Analysis of 30 Spinal Angiograms Falsely Reported as Normal in 18 Patients with Subsequently Documented Spinal
P Barreras1, D Heck2, B Greenberg3
1From the Transverse Myelitis Center, Department of Neurology (P.B., C.A.P.).
Background And Purpose:
The early diagnosis of spinal vascular malformations suffers from the nonspecificity of their clinical and radiologic presentations. Spinal angiography requires a methodical approach to offer a high diagnostic yield. The prospect of false-negative studies is particularly distressing when addressing conditions with a narrow therapeutic window. The purpose of this study was to identify factors leading to missed findings or inadequate studies in patients with spinal vascular malformations.
Materials And Methods:
The clinical records, laboratory findings, and imaging features of 18 patients with spinal arteriovenous fistulas and at least 1 prior angiogram read as normal were reviewed. The clinical status was evaluated before and after treatment by using the Aminoff-Logue Disability Scale.
Results:
Eighteen patients with 19 lesions underwent a total of 30 negative spinal angiograms. The lesions included 9 epidural arteriovenous fistulas, 8 dural arteriovenous fistulas, and 2 perimedullary arteriovenous fistulas. Seventeen patients underwent endovascular (11) or surgical (6) treatment, with a delay ranging between 1 week and 32 months; the Aminoff-Logue score improved in 13 (76.5%). The following factors were identified as the causes of the inadequate results: 1) lesion angiographically documented but not identified (55.6%); 2) region of interest not documented (29.6%); or 3) level investigated but injection technically inadequate (14.8%).
Conclusions:
All the angiograms falsely reported as normal were caused by correctible, operator-dependent factors. The nonrecognition of documented lesions was the most common cause of error. The potential for false-negative studies should be reduced by the adoption of rigorous technical and training standards and by second opinion reviews.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Aneurysm I: Introduction