Clavicle anatomical osteosynthesis plate breakage - failure analysis report based on patient morphological parameters
Rodica Marinescu1, Vasile Iulian Antoniac, Dan Ioan Stoia
1Department of Orthopedics and Traumatology, "Carol Davila" University of Medicine and Pharmacy, Bucharest, Romania; rodicamarinescu@ymail.com.
Abstract:
Clavicle fracture reported incidence is about 5% of fractures in adult; among them, those located in the middle third of the shaft represent more than 80% from the total of cases. Due to the special morphological and biomechanical constraints of the clavicle, several methods for restoring morphological integrity in these fractures are described, including conservative, non-surgical treatment. The last 10 years of clinical studies in the field have favored the surgical treatment for selected cases; several osteosynthesis implants are in use - mostly anatomical plates with specific advantages and documented complications. A failed anatomical clavicle plate was explanted and analyzed after a protocol using stereomicroscopy, scanning electron microscopy and energy dispersive spectrometry. Based on the computed tomography (CT) scan determination of patient morphological parameters, a finite elements analysis of the failure scenario was completed. The failure analysis has proved that the plate breakage had occurred in the point of maximal elastic stress and minor deformation. The clinical implication is that no hole should remain free of screw during clavicle plate fixation and the implant should be chosen based on patient morphological parameters. In comminuted clavicle fracture, anatomic bridging with locked plate technique may lead to implant failure due to increase of the stress in the midshaft area. Thorough knowledge of anatomy and morphology of complex bones like the clavicle is necessary. Modern osteosynthesis anatomical implants are still to be improved.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
Related Concept Videos
Changes in the Appendicular Skeleton with Age
Initially, the limb buds consist of a core of mesenchyme covered by a layer of ectoderm. The ectoderm at the end of the limb bud thickens to form a narrow crest called the apical ectodermal ridge. This ridge stimulates the underlying...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bone Formation by Intramembranous Ossification
The process begins when mesenchymal cells in the embryonic skeleton gather together and differentiate into osteogenic cells, which then develop into ...