Renal function in neonates with twin-twin transfusion syndrome treated with or without fetoscopic laser surgery

Lianne Verbeek1,2, Faiez A Joemmanbaks3, Jacoba M E Quak4

  • 1Division of Neonatology, Leiden University Medical Center, Leiden, The Netherlands. l.i.verbeek@lumc.nl.

The aim of this study is to investigate the short-term renal function in neonates with twin-twin transfusion syndrome (TTTS), treated with fetoscopic laser surgery (laser group) or conservatively (non-laser group). Creatinine and urea levels and urine output were recorded in the first week after birth. Primary outcome was short-term renal dysfunction, defined as a creatinine level of >100 μmol/L during the first week postpartum. We evaluated 312 twins (laser group, n = 274; non-laser group, n = 38). Median creatinine and urea levels were lower in the laser group than in the non-laser group (71 versus 82 μmol/L, p = 0.002). Short-term renal dysfunction was lower in the laser group compared to the non-laser group (7.2 versus 34.4%, p < 0.001). Within the laser group, creatinine levels were significantly higher in the subgroup with incomplete laser surgery compared to twins with successful laser surgery (76 versus 69 μmol/L, p = 0.018). No differences were found between donors and recipients except for a higher incidence of oliguria in donors in the non-laser group on day 1.