Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Diagnostic accuracy of nasal cannula versus microphone for detection of snoring
María Teresa Pérez-Warnisher1, Teresa Gómez-García1,2,3,4, Luis Fernando Giraldo-Cadavid5,6
1Department of Pulmonary Medicine, Hospital Universitario Fundaciœn Jiménez Díaz, Madrid, Spain.
Objective:
Snoring is a common reason for referral to a sleep unit. Although there are several instruments to measure snoring, there is no gold standard for this purpose. In this study, we determine the diagnostic accuracy of the cannula as compared with the microphone, which are the two most commonly used tools.
Study Design:
We performed a cross-sectional study of 75 patients who underwent baseline home sleep apnea testing for any reason.
Methods:
Snore intensity and percentage were assessed during Home sleep-apnea testing via nasal cannula and microphone in all patients. We performed a complete diagnostic accuracy analysis, assuming the microphone to be the reference instrument use in order to compare it with the cannula.
Results:
The intra-class correlation coefficient between the cannula and microphone for the percentage of snoring was 0.25. The Bland Bland-Altman analysis to determine the agreement regarding the percentage of snoring showed a lower limit of -57.73 and an upper limit of 20.30. A linear regression analysis of the differences produced a negative slope of -0.86. The receiver operating characteristic curve for severe snoring using the cannula produced an area under the curve of 0.67 (P = 0.019). The cannula showed a sensitivity of 57.89 and a specificity of 73.21.
Conclusion:
The nasal cannula showed poor reliability and accuracy for measuring snoring.
Level Of Evidence:
2b. Laryngoscope, 127:2886-2890, 2017.
More Related Videos
06:22Machine Learning-Based Cough Tone Classification: Diagnostic Exploration of Chronic Obstructive Pulmonary Disease and Respiratory Tract Infections
Published on: September 19, 2025
04:04Asthma Detection Research Based on Voice Signal Processing and Machine Learning
Published on: July 22, 2025
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Suctioning the Nasopharyngeal Airway
Equipment Required
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities: