Related Concept Videos

Enzyme Inhibition01:30

Enzyme Inhibition

Inhibitors are molecules that reduce enzyme activity by binding to the enzyme. In a normally functioning cell, enzymes are regulated by a variety of inhibitors. Drugs and other toxins can also inhibit enzymes. Some inhibitors bind to the enzyme’s active site, while others inhibit enzymatic activity by binding to other sites on the protein structure.
92.8K
Feedback Inhibition00:46

Feedback Inhibition

Biochemical reactions are occurring constantly in cells, converting starting substances to different products, usually with the help of enzymes that speed the reactions. Without enzymes, it would take far too long for most reactions to occur to be useful to the cell!
57.3K
PD Controller: Design01:26

PD Controller: Design

In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
662
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
408
Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
394
Inhibition of Cdk Activity02:34

Inhibition of Cdk Activity

The orderly progression of the cell cycle depends on the activation of Cdk protein by binding to its cyclin partner. However, the cell cycle must be restricted when undergoing abnormal changes. Most cancers correlate to the deregulated cell cycle, and since Cdks are a central component of the cell cycle, Cdk inhibitors are extensively studied to develop anticancer agents. For instance, cyclin D associates with several Cdks, such as Cdk 4/6, to form an active complex. The cyclin D-Cdk4/6 complex...
6.0K